
C
HAPTER
6
| VLAN Configuration
IEEE 802.1Q Tunneling
– 180 –
1.
New SPVLAN tags are added to all incoming packets, no matter how
many tags they already have. The ingress process constructs and
inserts the outer tag (SPVLAN) into the packet based on the default
VLAN ID and Tag Protocol Identifier (TPID, that is, the ether-type of the
tag). This outer tag is used for learning and switching packets. The
priority of the inner tag is copied to the outer tag if it is a tagged or
priority tagged packet.
2.
After successful source and destination lookup, the ingress process
sends the packet to the switching process with two tags. If the
incoming packet is untagged, the outer tag is an SPVLAN tag, and the
inner tag is a dummy tag (8100 0000). If the incoming packet is
tagged, the outer tag is an SPVLAN tag, and the inner tag is a CVLAN
tag.
3.
After packet classification through the switching process, the packet is
written to memory with one tag (an outer tag) or with two tags (both
an outer tag and inner tag).
4.
The switch sends the packet to the proper egress port.
5.
If the egress port is an untagged member of the SPVLAN, the outer tag
will be stripped. If it is a tagged member, the outgoing packets will
have two tags.
Layer 2 Flow for Packets Coming into a Tunnel Uplink Port
An uplink port receives one of the following packets:
◆
Untagged
◆
One tag (CVLAN or SPVLAN)
◆
Double tag (CVLAN + SPVLAN)
The ingress process does source and destination lookups. If both lookups
are successful, the ingress process writes the packet to memory. Then the
egress process transmits the packet. Packets entering a QinQ uplink port
are processed in the following manner:
1.
If incoming packets are untagged, the PVID VLAN native tag is added.
2.
If the ether-type of an incoming packet (single or double tagged) is not
equal to the TPID of the uplink port, the VLAN tag is determined to be a
Customer VLAN (CVLAN) tag. The uplink port’s PVID VLAN native tag is
added to the packet. This outer tag is used for learning and switching
packets within the service provider’s network. The TPID must be
configured on a per port basis, and the verification cannot be disabled.
3.
If the ether-type of an incoming packet (single or double tagged) is
equal to the TPID of the uplink port, no new VLAN tag is added. If the
uplink port is not the member of the outer VLAN of the incoming
packets, the packet will be dropped when ingress filtering is enabled. If
ingress filtering is not enabled, the packet will still be forwarded. If the
VLAN is not listed in the VLAN table, the packet will be dropped.
Summary of Contents for ES3510MA-DC
Page 1: ...Management Guide www edge core com 8 Port Layer 2 Fast Ethernet Switch...
Page 2: ......
Page 4: ......
Page 6: ...ABOUT THIS GUIDE 6...
Page 44: ...FIGURES 44...
Page 50: ...TABLES 50...
Page 52: ...SECTION I Getting Started 52...
Page 62: ...CHAPTER 1 Introduction System Defaults 62...
Page 80: ...CHAPTER 2 Initial Switch Configuration Managing System Files 80...
Page 82: ...SECTION II Web Configuration 82...
Page 98: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 98...
Page 126: ...CHAPTER 4 Basic Management Tasks Resetting the System 126...
Page 164: ...CHAPTER 5 Interface Configuration VLAN Trunking 164 Figure 57 Configuring VLAN Trunking...
Page 202: ...CHAPTER 7 Address Table Settings Configuring MAC Address Mirroring 202...
Page 452: ...CHAPTER 17 IP Services Displaying the DNS Cache 452...
Page 498: ...CHAPTER 19 Using the Command Line Interface CLI Command Groups 498...
Page 588: ...CHAPTER 22 SNMP Commands 588...
Page 596: ...CHAPTER 23 Remote Monitoring Commands 596...
Page 650: ...CHAPTER 24 Authentication Commands Management IP Filter 650...
Page 738: ...CHAPTER 27 Interface Commands 738...
Page 760: ...CHAPTER 29 Port Mirroring Commands RSPAN Mirroring Commands 760...
Page 782: ...CHAPTER 32 Address Table Commands 782...
Page 810: ...CHAPTER 33 Spanning Tree Commands 810...
Page 862: ...CHAPTER 35 VLAN Commands Configuring Voice VLANs 862...
Page 876: ...CHAPTER 36 Class of Service Commands Priority Commands Layer 3 and 4 876...
Page 932: ...CHAPTER 38 Multicast Filtering Commands Multicast VLAN Registration 932...
Page 956: ...CHAPTER 39 LLDP Commands 956...
Page 1020: ...CHAPTER 42 Domain Name Service Commands 1020...
Page 1026: ...CHAPTER 43 DHCP Commands DHCP Client 1026...
Page 1058: ...CHAPTER 44 IP Interface Commands IPv6 Interface 1058...
Page 1060: ...SECTION IV Appendices 1060...
Page 1066: ...APPENDIX A Software Specifications Management Information Bases 1066...
Page 1088: ...COMMAND LIST 1088...
Page 1097: ......