Default setting: siren/dialer enable 

 

Press 

 

 

 

 

 

 

                      User access code 

 

ACTIVATION TYPE 2 

 

This feature allows the dialer dial up the preset phone 

number in sequence when the Control Panel is 

triggered configured for arm or part-arm mode. 

 

Default setting: dialer enable 

 

Press 

 

 

 

 

 

 

               

  User access code 

 

Note: If Control Panel does not memorize any phone 

number, no action will be taken when Control Panel is 

triggered. 

 

TEST MODE 

 

Press 

 

 

 

 

 

 

                 

User access code 

 

The maximum allowable length of testing the system is 

10 minutes.    If 10 minutes expires, UI indication refers 

to “UI_Error” and exits test mode straight away.    If test 

is finished before 10 minutes is out, press 

  to 

exit this mode of which UI indication refers to 

“UI_Success”. 

 

While test is underway and the Control Panel receives 

RF signal from the detector, the Control Panel will ding 

dong. 

 

During test mode, press 

  keypad more than 3 

seconds, the Control Panel will emit system on/system 

off command to the wireless siren.   

 

During test mode, press 

  keypad more than 3 

seconds, the Control Panel will only dial up the first 

preset phone number. 

 

ALARM DURATION 

 

This is the maximum length of time that the Control 

Panel will sound for, following an intrusion.    Alarm 

duration can be set for either 1 or 3 minutes. 

 

Press 

 

 

 

 

 

 

                  User access code 

 

The maximum allowable length of inputting the alarm 

duration is 15 seconds. 

 

Press 

  for 1 minute 

Press 

  for 3 minute 

 

If 15 seconds expires or a sequence of incorrect input 

is entered 3 times, the Control Panel will exit this mode 

of which UI indication refers to “UI_Error”. 

 

JAMMING DETECTION 

 

This feature controls the Control Panels RF jamming 

detection circuitry, which if enabled, will continuously 

scan for radio jamming signals on the system operating 

frequency. 

 

Default setting: off 

 

Press 

 

 

 

 

 

 

                 

  User access code 

 

The maximum allowable length of selecting jamming 

detection on or off is 15 seconds. 

 

Press 

  for on 

Press 

  for off 

 

If 15 seconds expires or a sequence of incorrect input 

Summary of Contents for HA700

Page 1: ...stallation Operating Manual Fixing pack Control Panel 4 x 1 5V LR20 size D cell battery or 9V DC adapter option Motion Sensor 3 x 1 5V AA size battery option Door Window Contact Detector 3 x 1 5V AAA...

Page 2: ...EM ZONING The detector s may be set to operate on either Zone 1 Zone 2 or panic For ease of alarm verification it is recommended that the Zones are arranged logically eg downstairs detectors on Zone 1...

Page 3: ...rn their codes individually for the system to operate correctly For the Motion and Door Window Contact Detectors simply pressing the tamper switch located adjacent to the PCB will emit the ID code to...

Page 4: ...y Use this as a guide for your installation in conjunction with the recommendations contained in this manual for planning your intruder alarm system Before attempting to install your Alarm System it i...

Page 5: ...ss keypad whereas Panic zone press keypad on the Control Panel Note It is recommended that the smoke detector and flood detector are assigned to panic zone For wireless keypad press the tamper switch...

Page 6: ...screw on the metal mounting bracket completely 2 Use one finger from each hand to remove the battery cover from the rear of Control Panel 3 Fit 4 batteries to the battery compartment and ensure corre...

Page 7: ...7 down the Control Panel to get into the L shaped metal mounting bracket 8 Tighten the screw on the L shaped metal mounting bracket to secure the Control Panel...

Page 8: ...2 Under standby mode LED Sound Status Low Battery Zone 1 Zone 2 Panic Initial power up One long beep Green LED on for 3 seconds Jamming Alarm Rapid flash 3 times every 3 seconds 1 5 Zone Trigger 1 2...

Page 9: ...Disarm the system The Remote Controller also incorporates a Panic switch Activating the Panic switch will immediately initiate a Full Alarm condition whether the system is Armed or Disarmed unless the...

Page 10: ...n infra red radiation levels caused when a person moves within or across the devices field of vision If movement is detected an alarm signal will be emitted Note Motion Sensors will also detect animal...

Page 11: ...the sensor in a position where it is subject to excessive vibration 6 Ensure that the position selected for the motion sensor is within effective range of the Control Panel Note When the system is ar...

Page 12: ...n of the sensor to be checked during installation without triggering a Full Alarm ON Walk Test mode OFF Normal mode Note Remove batteries before setting the SW2 Refit batteries after setting the SW2 N...

Page 13: ...senses movement the LED behind the lens will flash In addition the Control Panel will ding dong If necessary adjust the detection range by changing the mounting position of the PCB within the sensor h...

Page 14: ...ED on the Detector will illuminate 4 Using the rear cover as a template mark the positions of fixing holes on the fixed part of the frame along the opening edge opposite the hinges using screws provid...

Page 15: ...er switch located at the rear cover of the Detector will emit the ID code to the Control Panel instantly subject to the Control Panel being set at the ID code learning mode TESTING THE DOOR WINDOW CON...

Page 16: ...There is a row of 8 DIP switches These switches set the House Code for the Control Panel and must be set to the same ON OFF combination as the House Code DIP switches in the wireless siren 1 2 3 4 5 6...

Page 17: ...s User access code When full alarm condition occurs disarm the alarm using remote controller wireless keypad or the keypad on the Control Panel as mentioned above RECORDING ALARM MESSAGE Press User ac...

Page 18: ...e which zone the detector should be assigned Users have a 6 second to input zone number If the detector is to be assigned in Zone 1 press keypad Zone 2 press keypad whereas Panic zone press keypad on...

Page 19: ...conds the Control Panel will emit system on system off command to the wireless siren During test mode press keypad more than 3 seconds the Control Panel will only dial up the first preset phone number...

Page 20: ...ength of selecting entry delay for on or off is 15 seconds Press for on Press for off If 15 seconds expires or a sequence of incorrect input is entered 3 times the Control Panel will exit this mode of...

Page 21: ...ol Panel Control Panel Press more than 3 seconds will generate full alarm condition Remote Controller Slide the Panic switch upwards The alarm will continue either for the alarm duration or until the...

Page 22: ...into Test mode before removing the Control Panel from the mounting bracket and disconnecting the power supply BATTERIES Before removing the battery cover on any device to replace the battery ensure th...

Page 23: ...23...

Reviews: