![EcoFasten Clickfit Installation Manual Download Page 20](http://html1.mh-extra.com/html/ecofasten/clickfit/clickfit_installation-manual_2354081020.webp)
VERSION: v3.0
REVISION DATE: 12/2/22
INSTALLATION GUIDE
GROUNDING
PAGE
19
NECESSARY COMPONENTS
One of the following grounding lugs (or any UL 2703 Compliant ground Lug):
• BurndyCL50-1TN Ground Lug (UL 2703 - E3514343 / UL 467-E9999)
• ILSCO SGB-4 Ground Lug (UL 2703 - E354420 / UL 467 - E34440)
• ILSCO GBL-4DBT (UL 2703 - E354420 / UL467 - E34440)
• ILSCO GBL-4DBTH (UL 2703 - E354420 / UL 467 - E34440)
• ILSCO GBL-4SS (UL 2703 - E354420 / UL 467 - E34440)
GROUNDING
*Equipment grounding wire should be sized in accordance with the National Electrical Code, NFPA70
and a minimum of 1/4” clearance is required between bare copper wires and aluminum components.