43
Defines the service due time.
This parameter is used in connection with the
Service time
counter. PAR94 defines the service time period in days, but
the
Service time
counter counts the hours. This means that if
you set the PAR94=1 (day), the
Service time
counter displays
24 (hours). Maximum value of the PAR94 is 255, which
means 6120 hours (255x24=6120). The display can show up
to 999 hours, value over 999 hours is displayed as Hi.
To reset the
Service time
counter, navigate to the
Reset
service timer
entry and press the Enter button to enter the
edit mode. The display shows
Off
. Press the right arrow
menu button to display
On
and then press the Enter button
to confirm.
Advanced water settings
No.
Parameter
Description
95
Stove Cool Fluid Entry Temp.
Diff.
In Stove mode with water pump only:
defines the temperature
threshold to switch off the stove (entering Cool fluid mode).
Other modes:
PAR95 and PAR96 are not used.
96
Stove Cool Fluid Exit Temp.
Diff.
In Stove mode with water pump only:
defines the restart level
from Cool Fluid.
Other modes:
PAR95 and PAR96 are not used.
97
T1-T2 for Min. Modulation
Speed
Minimum temperature difference for modulation (in °C):
When normal regulation is used, defines how many degrees
before the desired temperature is reached the controller starts
to decrease the burning power.
NOTE: When modulation water pump is used.
Leveltronic settings (Monitoring Fuel autonomy with UltraSonic sensor)
An ultrasonic pellet level sensor can be used to detect the level of fuel in the container with the 5mm precision.
User interface displays a warning (when fuel level reaches “low”) or an alarm (when fuel level reaches “empty”),
based on sensor detection. With advanced feeder settings (hidden parameters) LevelTronic data can also be
used for automatic control of fuel autonomy function. In this case the user interface displays time to empty
magazine level (in hours). If the magazine is re-filled at any time, fuel autonomy value is automatically reset,
based on fuel level change, monitored by LevelTronic.
No.
Parameter
Description
98
Full Level
Full magazine sensor signal (in cm):
Defines the full magazine level.
99
Low Level
Warning level sensor signal (in cm):
Defines the warning magazine level.
100
Empty Level
Empty Magazine sensor signal (in cm):
Defines the empty magazine level. At this level the combustion
device is turned off to prevent feeder emptying and thus enables
faster restart (no need to wait for the feeder to refill).
Other settings