desired room temperature for the selected time period. Confirm the program settings by pressing Enter. Repeat the
procedure to set the programs.
Example:
Program 1
Program 2
Program 3
Program 4
Program 5
Program 6
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
5:30
7:30
8:00
11:30 12:00
23:00 17:00 23:00 20:00 22:30 4:00
7:00
16⁰C
18⁰C
19⁰C
18⁰C
17⁰C
15⁰C
To set the programs for each day of the week, press the menu button to enter the
Time
context and then press the
edit button to select the
Weekly timer days
. The display shows (4). Press Enter to select
Monday
, display shows (d1),
and then press Enter again to access the edit mode for Monday. The 1. program value is blinking. With the edit
buttons set the desired program. Then press the right menu button. The 2. program value is blinking. Set the desired
program. Confirm the program settings by pressing Enter. Repeat the procedure to set the programs for all weekdays.
Example:
To enable or disable the operation of the combustion system with the weekly timer programs, press the menu button
to enter the
Time
context and then press the edit button to select the
Weekly timer
ON/OFF. Press Enter and toggle
the weekly timer on or off. If you disable the weekly timer operation, set the combustion system operation manually.
Example:
You can disable the weekly timer programs in the time of vacations.
Program overlapping:
If the programs overlap, the program with higher number assumes priority (for example: P2 assumes priority over P1;
P4 over P3, P2 and P1; P6 over P5, P4, P3, P2 and P1).
The following figure shows the working of combustions system in case of P1, P2 and P3 programs overlapping.