3.0
INSTALLATION
3.1 General rules
Knowing that the proper assembly is very important, as well as the proper connection of the exhaust gas system
and that the possible errors made during the assembly are not covered by the warranty of MANUFACTURER , our
company advices the installation to be made after the following checks:
- Minimum volume of the space where the pellet stove is installed (avoid spaces smaller than 40m
3
);
- Provide good air flow;
- Observe all the norms;
- Proper operation of the exhaust gas system;
You should also observe the following legal normatives:
- Bans on installation
- The right to occupy a space
It is not allowed an installation of the pellet stove in bedrooms, toilets, and in spaces where already exists another
heating body without sufficient air intake (pellet stove, fireplace etc.). It is not allowed the installation of the pellet
stove in spaces containing explosive materials.
The installation of the pellet stove should be made in accordance to all practical knowledge. The space around the
pellet stove should be made of stone, cement or other fireproof material. The pellet stove generates heat around the
burner. Therefore, you should avoid contact of inflammable materials with the burner (alcohol, paper, plastics …)
Minimal distance from the inflammable materials is 200 mm.
- If the floor is made of inflammable material (parquet ...) it should be adequately isolated.
- The metal pipes intended for the gas exhaust should be at a distance of 1,5 m from inflammable materials
.
- We recommend that the pellet stove should be installed as closer as possible to the exhaust gas system, always
having maximum 3+1T curves and maximum 3 m of horizontal flow with minimal elevation of 3-5%.
As soon as the place of installation is defined, remove the cardboard and the other protective material and check
whether the door is properly closed
.
3.2 CONNECTION OF THE OUTER AIR PIPE