Troubleshooting
The Fumis ALPHA keyboard provides notifications and warnings for alerts and errors, which can occur when using the
Fumis ALPHA controller. The alarm icons indicate a problem. An alert notification is indicated with the blinking icons,
errors are indicated with continuously lit icons. In case of an alert, the combustion system is still operational, in case of
an error the combustion system is seriously malfunctioning and the service personnel should be contacted.
Each alert and error has a code, which can be used to identify the problem. To display the code, press and hold the
Escape button. In case there is no information on the alert/error code, the display
shows ----.
Low fuel
Indication:
Icon No fuel is blinking
Code: A001
Cause: When the fuel in the container reaches the
Low fuel
level, the notification is triggered. This notification is
available if you are using the
Fuel autonomy
option or your combustion system is equipped with the fuel level sensor.
Solution: Refill the fuel container. If you are using the
Fuel autonomy
option, reset this setting to
Full
by pressing the
button ON/OFF on the user interface.
No fuel
Indication:
Icon No fuel is on
Code: ----
Cause: When the fuel in the container runs out, the notification is triggered. The combustion system turns off and
cannot be restarted.
Solution: Refill the fuel container. If you are using the
Fuel autonomy
option, reset this setting to
Full
by pressing the
button ON/OFF on the user interface.
Burning chamber or chimney dirty
Indication:
Icon Cleaning is blinking
Code: A003
Indication:
Icon Cleaning is on
Code: ----
Cause: The burning chamber or chimney are dirty and require cleaning. There is too much ash or unburned pellets in
the burning chamber, or chimney is getting congested with soot.
Solution: Check and empty the burning chamber or contact the service personnel to sweep the chimney.
Low battery
Indication:
Icon Service is blinking
Code: A004
Cause: The Fumis ALPHA controller battery is getting low. The combustion system is still operational.