The Burner Reset button on the Control Box illuminates to indicate that a lockout has occurred.
In the event of the Burner locking out, do not attempt to restart the Burner by pressing the Reset Button on
the Burner Control Box for at least 2 minutes. A Bi-metallic timer within the Control Box has a minimum
cooling time of 45 seconds thus the 2 minute interval will ensure that this Bi-metallic timer has cooled and is
therefore in a position where it may be reset.
RESTARTING AFTER LOCKOUT
When lockout has occurred, inspect for any obvious causes e.g. oil leaks. Also check the fuel line from the
tank to the boiler and that any oil shut off valve has not been inadvertently closed.
RESTART
-
Check there is adequate oil in the storage tank.
-
Check oil supply valves are open
-
Switch on heating system (e.g. Time Clock)
-
Press the Burner Reset Button on the burner Control Box, which will be illuminated. The Burner Reset
Button (illuminated)(Fig 1) will go out and the burner will commence the ignition start sequence. After
15 seconds the Burner should fire normally.
PLEASE NOTE:
Should the Burner not start, the lockout indicator, on the Control Box/Burner Reset
Button will illuminate again.
- Wait at least 3 minutes and press the Burner Reset Button again.
Failure to start a second time indicates a fault requiring attention.
In the event of a second failure to start:
-
Switch off electrical supply
-
Call service engineer.
REGULATIONS
The installation of oil-fired boilers should comply with the following standards and codes of practice:
- BS5449
Forced circulation hot water heating systems for domestic use.
- BS5410-Part 1 Oil installations up to 45kw
- BS7593
Water treatment of hot water central heating systems
- BS7671
Electrical Regulations
- Building Regulations Part 1L and J 2002 England and Wales, Part F Scottish Regulations and
Technical Booklet L Northern Ireland.
- OFTEC
Codes of Practice Published or Recommended.
After installing, the system needs to be flushed with a cleanser like Fernox Heavy Duty Restore, for fast-
acting removal of lime scale, black sludge (magnetite) and other deposits from the boiler and the central
heating system. Then add a Fernox protector to give long-term protection of the central heating system
against internal corrosion lime scale formation.