A flexible oil pipe is supplied to connect the burner to the incoming oil supply pipe.
IMPORTANT NOTES:
-
If sitting oil tank above burner height, use single supply pipe only.
-
If sitting oil tank below burner height, use twin pipe supply or Tiger loop.
-
Please refer to Burner Manual for conversion to oil pump for two pipe system.
ELECTRICAL ENTRY
The electrical supply to the boiler must be wired using a double pole-isolating switch 230v/50hz, fused 5
amps. The mains supply must be connected with the boiler dual stat, the supply will then continue down to
the burner control box. The burner is supplied with a three wire cable plug which allows disconnection for
maintenance.
General Data
Electrical Supply. 240w-50hz
Oil Supply Connection ¼” BSP
Fuel: 28 Second
High Limit Stat: Manual Reset
Maximum Control Thermostat Setting 85°C
Maximum Operating Pressure:
3 Bar – 45psi – 28m Static head room 92ft
Draught Limit
Min 12.5 Nm
2
– 0.05” WG
Max 33.0 Nm
2
– 0.12” WG