background image

1. Introduction 

 
Thank  you  for  choosing  to  purchase  the  condensed  oil,  balanced  flue,  Eco  Range  cooker. 
Each  cooker  is  manufactured  and  assembled  by  hand  in  our  factory.  This  appliance  is 
designed  to  be  capable  of  operating  for  long periods  of  time.  With  correct  installation  and 
use  your  Eco  Range  cooker  will  provide  many  years  of  satisfactory  service  and  cooking 
enjoyment. 
 
The  appliance  consists  of  two  hotplates,  a  top  oven  and  a  bottom  oven  or  warming 
compartment. The left sided hotplate is designed for more rapid heating suitable for frying 
and  boiling,  whereas  the  right  sided  hotplate  is  more  suitable  for  slower  cooking  and 
simmering. Hotplate covers are provided to prevent heat losses when not cooking. The two 
top  ovens  operate  to  provide  a  consistent  temperature  controlled  environment  for  all  your 
cooking and baking needs. The bottom oven operates at lower temperatures and is suitable 
for slow cooking or merely as a warming compartment, depending on the control setting. 

 

These  instructions  detail  how  to  get  the  most  from  your  cooker,  as  well  as  fundamental 
information on how the cooker shall be installed, maintained and used in a safe and practical 
manner. 

It  is  important  that  some  time  is  taken  to  read  these  instructions  carefully 

before installation and use of the appliance. 
 

In  order  for  the  warranty  to  remain  valid  it  is  imperative  that  the  appliance  be  installed  in 
compliance with all relevant national and regional regulations.  
 
A competent heating and plumbing engineer must design and approve the proposed system.  
 

The warranty of your Eco Range Cooker applies to products sold in the UK and Eire 
only.  For  products  sold  outside  of  these  areas  please  contact  the  manufacturer  for 
details warranty authorisation.  

 

 

2. Safety Instructions 

 
Safety First: 

This is a heating appliance; therefore it can become very hot when in service. 
Young children and pets should be kept a safe distance from the cooker.  
Ceiling mounted clothes dryers are strongly unadvised as they can present a fire hazard, this 
also includes leaving towels on the handrail of the cooker.  
Pans, especially chip pans, should not be left unattended on the Eco Range cooker. 

Read and understand this booklet before installing and operating this appliance. 
 

 

This appliance must be installed in accordance with the rules in force and used only in a 
well ventilated space.

 

 

 

The appliance must only be installed and serviced by a suitably qualified and registered 
technician.  

 

 

The  appliance  shall  not  be  altered  in  any  way  and  only  approved  spare  parts  shall  be 
used. Failure to do so will invalidate any warranty or guarantee.

 

Summary of Contents for 15/21

Page 1: ...Eire GB IE Instructions for Use Installation and Servicing This appliance must be installed in accordance with the regulations in force and only used in an adequately ventilated space Please read thes...

Page 2: ...ime is taken to read these instructions carefully before installation and use of the appliance In order for the warranty to remain valid it is imperative that the appliance be installed in compliance...

Page 3: ...ended when applicable Children should be supervised at all times if in the vicinity of the cooker In the interest of hygiene and safety the cooker should be kept clean at all times The cooker is desig...

Page 4: ...when works are complete Always ensure appliance is electrically dead prior to working on the electrics 3 Technical Specification Appliance type Cooker and Space heater Cooker Burner System Eco Flame...

Page 5: ...ble for deep fat frying shallow frying and boiling The surfaces of the hotplates are ground flat and it is therefore recommended that all utensils used have a solid flat base to come in complete conta...

Page 6: ...r remains fully functional and in a safe condition 5 0 Delivery and Transport Your Eco Range Cooker is an extremely heavy and solid appliance When attempting to move or transport your cooker please ta...

Page 7: ...d flue allows the cooker to be placed against an outside wall with either rear or top outlet concentric flue Maximum length of rear flue 500mm Maximum length of top outlet flue 300mm vertical 500mm ho...

Page 8: ...f 3 drop 6 With suitable material make a good flue hole 7 Fit the terminal to the pipes whilst ensuring the inner pipe has adequate clearance between terminal end and outlet min 50 mm Secure terminal...

Page 9: ...t go up the chimney have quite a high temperature 200 C 260 C and are made up of a few different types of gases A condensing boiler is designed so that these flue gases pass through a stainless steel...

Page 10: ...n the boiler is controlled and maintained by the Boiler Control Thermostat located on the boiler control panel TEMPERATURE SETTINGS The Boiler Control Thermostat has a range of 50 C to 80 C The recomm...

Page 11: ...URNER LOCKOUT The burner has an independent control system Burner Control Box this includes a flame detector Photocell which senses the presence of a flame In the event of a flame failure the burner c...

Page 12: ...rner should fire normally PLEASE NOTE Should the Burner not start the lockout indicator on the Control Box Burner Reset Button will illuminate again Wait at least 3 minutes and press the Burner Reset...

Page 13: ...waste drainage system Soil vent stack External Drainage system External condensate absorption point NOTE condensate pipe work must fall at least 50mm per metre towards the outlet ensuring all joints a...

Page 14: ...RECOMMENDED FLUE POSITION...

Page 15: ...OIL SUPPLY...

Page 16: ...oiler must be wired using a double pole isolating switch 230v 50hz fused 5 amps The mains supply must be connected with the boiler dual stat the supply will then continue down to the burner control bo...

Page 17: ...out debris Clean baffle assembly Pull out inserts from stainless steel heat exchanger and clean before replacing Ensure stainless steel heat exchanger is thoroughly cleaned Empty and clean condensing...

Page 18: ...BOILER SIZE NO OF INSERTS FROM L H SIDE OF CONDENSER REMAINING TUBES WITHOUT INSERTS 15 21 KW 10 6 1 SET OF BAFFLES 15 21 KW...

Page 19: ...front A service access space of at least 700mm should be made available at the front of the boiler THE HEARTH The temperature of the surface below the boiler is less than 85 C If the floor under the...

Page 20: ...to the boiler De pressurise heating system and check expansion vessel pre charge is the same as the cold fill pressure of the heating system Expansion vessel pre charge must not exceed 1 5 bar Remove...

Page 21: ...al operating temperature Check the smoke reading Measure the Co2 Measure net flue gas temperature Check domestic hot water flow and hot temperature is acceptable to the householder PLEASE NOTE Reducin...

Page 22: ...n and time clock is calling for heat Mains indicator green should be illuminated If green light is not illuminated and fuse has been checked then heating system charge may be low check black needle on...

Page 23: ...er using recognised test equipment and that the relevant section of the latest edition of BS 5410 Part 1 is read and fully adhered to The following warranty registration page should be completed by th...

Page 24: ...NICIANS DETAILS Technician s Name in BLOCK CAPITALS Technician s Competent Persons OFTEC Registration Number Address Town County Postcode Technician s Signature Cooker Boiler Burner pressure psi CO2 C...

Page 25: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 26: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 27: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 28: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 29: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 30: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 31: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 32: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 33: ...S Engineer s Name in BLOCK CAPITALS Engineers Registration Number Engineer s Signature Date COMBUSTION ANALYSIS Cooker Boiler Pump pressure CO2 CO ppm Flue Gas Temperature CO CO2 Efficiency Engineer s...

Page 34: ...it is consequently acknowledged that errors and omissions may occur This publication is intended only to assist the reader in the use of our products Eco Range Cookers will not accept any liability fo...

Page 35: ...Eco Range Cookers 60 Wincheap Canterbury Kent CT1 3RS info ecorangecooker co uk www ecorangecooker co uk...

Reviews: