Note:
28 sec fuel must only be used on ECO Range Cookers & boilers
SERVICING INSTRUCTIONS
A competent service engineer OFTEC registered should be appointed on an annual basis.
Remove inspection door, burner and baffle assembly
Brush down the inside of the heat exchanger and vacuum out debris
Clean baffle assembly
Pull out inserts from stainless steel heat exchanger and clean before replacing.
Ensure stainless steel heat exchanger is thoroughly cleaned.
Empty and clean condensing trap (Fig.4)
Inspect and clean burner assembly, and replace with new nozzle (see burner manual)
Renew any insulation e.g. inspection door or inside base of heat exchanger
Reassemble baffles and replace inspection door.
Replace paper oil filters
Test oil pressure and test combustion.
Summary of Contents for 15/21
Page 14: ...RECOMMENDED FLUE POSITION...
Page 15: ...OIL SUPPLY...