background image

30" (76.2 CM) AND 36" (91.4 CM) ELECTRIC 

DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS 

INSTRUCTIONS D’INSTALLATION DE LA TABLE DE 

CUISSON ÉLECTRIQUE AVEC ASPIRATION PAR LE BAS DE 

30" (76,2 CM) ET 36" (91,4 CM)     

W10197059A

Table of Contents/Table des matières

COOKTOP SAFETY .....................................................................................2

INSTALLATION REQUIREMENTS .............................................................3

Tools and Parts .........................................................................................3
Location Requirements.............................................................................3
Venting Requirements ..............................................................................5
Venting Methods.......................................................................................6
Electrical Requirements  ...........................................................................7

INSTALLATION INSTRUCTIONS ...............................................................8

Prepare Cooktop.......................................................................................8
Install Foam Strip ......................................................................................8
Rotate Blower ...........................................................................................8
Install Cooktop ........................................................................................10
Make Electrical Connection....................................................................10
Complete Installation ..............................................................................11

SÉCURITÉ DE LA TABLE DE CUISSON ............................................ 13

EXIGENCES D'INSTALLATION........................................................... 14

Outillage et pièces ............................................................................. 14
Exigences d'emplacement ................................................................ 14
Exigences concernant l'évacuation .................................................. 16
Méthodes d'évacuation..................................................................... 17
Spécifications électriques ................................................................. 18

INSTRUCTIONS D’INSTALLATION .................................................... 19

Préparation de la table de cuisson.................................................... 19
Installation de la bande de mousse .................................................. 19
Rotation du ventilateur ...................................................................... 20
Installation de la table de cuisson ..................................................... 21
Raccordement électrique .................................................................. 21
Achever l'installation.......................................................................... 22

IMPORTANT:

 

Save for local electrical inspector's use.

IMPORTANT :

À conserver pour consultation par l'inspecteur local des installations électriques.

Summary of Contents for 36" (91.4 CM) ELECTRIC DOWNDRAFT COOKTOP

Page 1: ...8 Rotate Blower 8 Install Cooktop 10 Make Electrical Connection 10 Complete Installation 11 S CURIT DE LA TABLE DE CUISSON 13 EXIGENCES D INSTALLATION 14 Outillage et pi ces 14 Exigences d emplacemen...

Page 2: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safe...

Page 3: ...ing codes and ordinances When installing cooktop use minimum dimensions given To eliminate the risk of burns or fire by reaching over the heated surface units cabinet storage space located above the s...

Page 4: ...m recommended minimum cabinet to motor clearance G 16 41 6 cm H 4 11 8 cm A B C D E G F H A B C A B C D E G H F A 30 76 2 cm on 30 76 2 cm models 36 91 4 cm on 36 91 4 cm models B Combustible area abo...

Page 5: ...bows too close together can cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using a 6...

Page 6: ...2 cm round metal vent C 16 40 6 cm maximum D 6 15 2 cm round PVC sewer pipe E 6 15 2 cm round metal vent F 6 15 2 cm round PVC coupling G Concrete slab H 6 15 2 cm round PVC sewer pipe I 6 15 2 cm ro...

Page 7: ...CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No O M91 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protec...

Page 8: ...ve the removable grease filter by lifting the filter out 5 Using 2 or more people remove the cooktop from the carton 6 Use foam end caps from the packaging as a work surface for the floor or counterto...

Page 9: ...d ratchet 6 Reinstall the four plastic plugs To rotate blower motor NOTE The Top label location on the blower motor is at the 9 o clock position 1 Using a ratchet with a socket and supporting the moto...

Page 10: ...e Power Supply to 4 Wire Cable from Cooktop IMPORTANT Use the 4 wire cable from home power supply in the U S where local codes do not allow grounding through neutral New Branch circuit installations 1...

Page 11: ...d household cleaner and warm water to clean cooktop before use Dry thoroughly with a soft cloth For more information see the Cooktop Care section of the Use and Care Guide 5 Read Cooktop Use in the co...

Page 12: ...12 Notes...

Page 13: ...cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Page 14: ...r les dispositions de tous les codes et r glements en vigueur Lors de l installation de la table de cuisson utiliser les dimensions minimums indiqu es Afin de supprimer le risque de br lures ou d ince...

Page 15: ...41 6 cm H 4 11 8 cm A B C D E G F H A B C A B C D E G H F A 30 76 2 cm sur les mod les de 30 76 2 cm 36 91 4 cm sur les mod les de 36 91 4 cm B Zone de mati re combustible au dessus du plan de travai...

Page 16: ...n de l air Ne pas utiliser un coude de 5 12 7 cm dans un syst me de 6 15 2 cm ou x 10 8 3 x 25 4 cm Ne pas r duire le syst me une longueur de 5 12 7 cm apr s avoir utilis des raccords de 6 15 2 cm ou...

Page 17: ...ssoire de filtration sans conduit Jenn Air contacter votre concessionnaire Jenn Air ou composer le 1 800 JENNAIR 1 800 536 6247 Option 1 D charge travers le toit Option 2 D charge travers le mur A Bou...

Page 18: ...ion et tous les codes et r glements locaux Pour obtenir un exemplaire des normes et codes ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA Internation...

Page 19: ...me aux codes locaux et aux pratiques de c blage accept es par l industrie INSTRUCTIONS D INSTALLATION Pr paration de la table de cuisson D terminer l emplacement final de la table de cuisson 1 Ouvrir...

Page 20: ...desserr s 5 Resserrer chaque crou l aide de la douille de de la rallonge et de la cl cliquet 6 R installer les 4 bouchons d obturation en plastique Pour faire pivoter le moteur du ventilateur REMARQU...

Page 21: ...it le cas ch ant 5 Voir le Tableau des options de raccordement lectrique pour terminer l installation correspondant votre type de raccordement lectrique Options de raccordement lectrique C ble 4 condu...

Page 22: ...ff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les outils 3 Jeter recycler tous les mat riaux d emballage 4 Utiliser une solution d eau ti de et de nettoyant m...

Page 23: ...23 Notes...

Page 24: ...r serv s Registered Trademark TM Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e TM Marque de commerce de Jenn Air U S A Emploi sous licence par Maytag Limit...

Reviews: