background image

7

Jenn-Air

®

 Duct Free Filter Accessory Kit

On select downdraft models, the Jenn-Air

®

 Duct Free Filter 

Accessory Kit Part Number JDX7000WX is now available. The 
Jenn-Air

®

 Duct Free Filter Accessory Kit is ideal for both new 

construction and kitchen renovation projects because it provides 
an easy alternative to the installation of metal ducting and venting 
in the downdraft system outside the home. The kit includes all 
required hardware, one filter and complete installation 
instructions. For more information on the Jenn-Air

® 

Duct Free Filter 

Accessory Kit, contact your Jenn-Air

®

 dealer or call 

1-800-JENNAIR (1-800-536-6247).

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent 
feet (meters) for each vent piece used in the system.

Example vent system

NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce performance.

Electrical Requirements 

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Check with a qualified electrical installer if you are not sure the 
cooktop is properly grounded.
Make sure that the electrical connection and wire size are 
adequate and in conformance with the National Electrical Code, 
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, 
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest 
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

Before You Make the Electrical Connection:

To properly install your cooktop, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC only 
electrical supply is required on a separate, 40-amp circuit 
(36" [91.4 cm] models) or 40-amp circuit (30" [76.2 cm] 
models), fused on both sides of the line. 

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft
(0.8 m) 

90° elbow

5.0 ft
(1.5 m)

6" (15.2 cm) 
wall cap

0.0 ft
(0.0 m)

3

¹⁄₄

" x 10" (8.3 cm x 25.4 cm) 

to 6" (15.2 cm) transition

4.5 ft
(1.4 m)

6" (15.2 cm) to 3

¹⁄₄

" x 10" 

(8.3 cm x 25.4 cm) transition

1 ft
(0.3 m)

3

¹⁄₄

" x 10" (8.3 cm x 25.4 cm) 

to 6" (15.2 cm) 90° elbow 
transition

5.0 ft
(1.5 m)

6" (15.2 cm) to 3

¹⁄₄

" x 10" 

(8.3 cm x 25.4 cm) 90° elbow 
transition

5.0 ft
(1.5 m)

3

¹⁄₄

" x 10" (8.3 cm x 25.4 cm)  

90° elbow

5.0 ft
(1.5 m) 

3

¹⁄₄

" x 10" (8.3 cm x 25.4 cm) 

flat elbow

12.0 ft
(3.7 m)

3

¹⁄₄

" x 10" (8.3 cm x 25.4 cm) 

wall cap

0.0 ft
(0.0 m)

1- 90° elbow

= 5 ft (1.5 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

1 - wall cap

= 0 ft (0 m)

System length

= 13 ft (3.9 m)

90˚ elbow

2 ft 

(0.6 m)

6 ft (1.8 m)

wall cap

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper wire.

Electrically ground cooktop.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

Summary of Contents for 36" (91.4 CM) ELECTRIC DOWNDRAFT COOKTOP

Page 1: ...8 Rotate Blower 8 Install Cooktop 10 Make Electrical Connection 10 Complete Installation 11 S CURIT DE LA TABLE DE CUISSON 13 EXIGENCES D INSTALLATION 14 Outillage et pi ces 14 Exigences d emplacemen...

Page 2: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safe...

Page 3: ...ing codes and ordinances When installing cooktop use minimum dimensions given To eliminate the risk of burns or fire by reaching over the heated surface units cabinet storage space located above the s...

Page 4: ...m recommended minimum cabinet to motor clearance G 16 41 6 cm H 4 11 8 cm A B C D E G F H A B C A B C D E G H F A 30 76 2 cm on 30 76 2 cm models 36 91 4 cm on 36 91 4 cm models B Combustible area abo...

Page 5: ...bows too close together can cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using a 6...

Page 6: ...2 cm round metal vent C 16 40 6 cm maximum D 6 15 2 cm round PVC sewer pipe E 6 15 2 cm round metal vent F 6 15 2 cm round PVC coupling G Concrete slab H 6 15 2 cm round PVC sewer pipe I 6 15 2 cm ro...

Page 7: ...CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No O M91 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protec...

Page 8: ...ve the removable grease filter by lifting the filter out 5 Using 2 or more people remove the cooktop from the carton 6 Use foam end caps from the packaging as a work surface for the floor or counterto...

Page 9: ...d ratchet 6 Reinstall the four plastic plugs To rotate blower motor NOTE The Top label location on the blower motor is at the 9 o clock position 1 Using a ratchet with a socket and supporting the moto...

Page 10: ...e Power Supply to 4 Wire Cable from Cooktop IMPORTANT Use the 4 wire cable from home power supply in the U S where local codes do not allow grounding through neutral New Branch circuit installations 1...

Page 11: ...d household cleaner and warm water to clean cooktop before use Dry thoroughly with a soft cloth For more information see the Cooktop Care section of the Use and Care Guide 5 Read Cooktop Use in the co...

Page 12: ...12 Notes...

Page 13: ...cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Page 14: ...r les dispositions de tous les codes et r glements en vigueur Lors de l installation de la table de cuisson utiliser les dimensions minimums indiqu es Afin de supprimer le risque de br lures ou d ince...

Page 15: ...41 6 cm H 4 11 8 cm A B C D E G F H A B C A B C D E G H F A 30 76 2 cm sur les mod les de 30 76 2 cm 36 91 4 cm sur les mod les de 36 91 4 cm B Zone de mati re combustible au dessus du plan de travai...

Page 16: ...n de l air Ne pas utiliser un coude de 5 12 7 cm dans un syst me de 6 15 2 cm ou x 10 8 3 x 25 4 cm Ne pas r duire le syst me une longueur de 5 12 7 cm apr s avoir utilis des raccords de 6 15 2 cm ou...

Page 17: ...ssoire de filtration sans conduit Jenn Air contacter votre concessionnaire Jenn Air ou composer le 1 800 JENNAIR 1 800 536 6247 Option 1 D charge travers le toit Option 2 D charge travers le mur A Bou...

Page 18: ...ion et tous les codes et r glements locaux Pour obtenir un exemplaire des normes et codes ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA Internation...

Page 19: ...me aux codes locaux et aux pratiques de c blage accept es par l industrie INSTRUCTIONS D INSTALLATION Pr paration de la table de cuisson D terminer l emplacement final de la table de cuisson 1 Ouvrir...

Page 20: ...desserr s 5 Resserrer chaque crou l aide de la douille de de la rallonge et de la cl cliquet 6 R installer les 4 bouchons d obturation en plastique Pour faire pivoter le moteur du ventilateur REMARQU...

Page 21: ...it le cas ch ant 5 Voir le Tableau des options de raccordement lectrique pour terminer l installation correspondant votre type de raccordement lectrique Options de raccordement lectrique C ble 4 condu...

Page 22: ...ff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les outils 3 Jeter recycler tous les mat riaux d emballage 4 Utiliser une solution d eau ti de et de nettoyant m...

Page 23: ...23 Notes...

Page 24: ...r serv s Registered Trademark TM Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e TM Marque de commerce de Jenn Air U S A Emploi sous licence par Maytag Limit...

Reviews: