![Eco Power Equipment IAQH Series Installation And User Instructions Manual Download Page 62](http://html1.mh-extra.com/html/eco-power-equipment/iaqh-series/iaqh-series_installation-and-user-instructions-manual_3999244062.webp)
IAQH-1000 Manual
8.2 Switching Between Fuel Sources
8.3
It is common for customers who use the IAQH-1000 heating system to switch between
fuel sources as they become available during the construction process. This typically
involved starting projects on propane fuel, and switching to natural gas when it becomes
available.
The unit is equipped with a quick change lockable orifice valve to switch between fuel orifices.
The valve is labeled and includes a lockable connection to allow the position to be set, and
locked.
It is very important that the valve be set in the correct position for your fuel selection, ITEM 17 is
the orifice valve, and is open for natural gas, and closed for propane operation.
Each time a fuel change occurs, following the section 4.3 startup and commissioning
instructions.
62
Summary of Contents for IAQH Series
Page 2: ...2 Eco Power Equipment Ltd ...
Page 21: ...IAQH 1000 Manual 21 ...
Page 22: ...IAQH 1000 Manual 22 ...
Page 50: ...IAQH 1000 Manual Gas Connection and Burner Setup FIgure GT1 50 ...
Page 56: ...IAQH 1000 Manual Figure RTC Figure Midco 1 56 ...