57
Rated Voltage [a.c.V]
230 (±2%)
Norminal Frequency [Hz]
50/60 (±0.2%)
Rated Output Current [a.c.A]
18.8
24
26.1
31.3
Inrush current[a.c.A]
16 a.c.A (peak), 11.3 us (duration)
Max. output fault current[a.c.A]
57 (peak), 40 (rms)
EPS output Maximum output
overcurrent protection[a.c.A]
40
Switch time [ms]
< 10
THDv @ Linear Load [%]
< 2
Power Factor
-0.8...+0.8
Efficiency
PV Max. Efficiency[%]
97.6
PV Europe Efficiency[%]
97
PV Max. MPPT Efficiency[%]
99.9
Battery Charge by PV Max.
Efficiency[%]
98
Battery Discharge Efficiency[%]
96.7
Protection
Over/Under voltage protection
Yes
DC isolation protection
Yes
DC injection monitoring
Yes
Residual current detection
Yes
Anti-islanding protection
Yes
Over load protection
Yes
Battery Input reverse polarity
protection
Yes
PV reverse polarity protection
Yes
Surge protection
Yes
Over heat protection
Yes
General Data
WH-BXB5.12
WH-BXB10.24
Dimension (W/D/H)[mm]
550*233*1125
550*233*1750
Dimension of Packing
(W/D/H)[mm]
645*302*1370
655*302*2055
Net weight [kg]
68
115
Gross weight [kg]
78
130
Operation Temp [°C]
-10...+55
Relative Humidity[%]
0...95
Altitude [m]
<= 3000
Ingress Protection
IP65
Cooling
Natural
Inverter Topology
Non-isolated
Over voltage category
Ⅲ(AC), Ⅱ(DC)
Protective class
Class Ⅰ
Active anti-islanding method
frequency shift
Human Interface
LED/APP
Summary of Contents for WH-SPHA3.6H-5.12kWh
Page 10: ...10 Terminals of BESS...
Page 14: ...14 500 1 500 mm beside the BESS 2 800 mm above the BESS 3 500 mm before the BESS...
Page 35: ...35...
Page 48: ...48 Group curves This page shows the 28 different data curves of the device...
Page 49: ...49 Configuration Battery setting...
Page 59: ...59 9 2 Battery label...
Page 60: ...60...