Note: The back-up PE line and rack earth must be grounded properly and effectively.
Otherwise the back-up function may be abnormal when the grid fail.
2.3.4 Power Meter
The electricity meter should be mounted and connected at the grid transition point
so that it can measure the grid reference and feed-in power.
CT meter ratio and accuracy table
Manufacturer
Model
CT ratio
Accuracy
Acrel Co., Ltd
ACR10R-D16TE
3000
0.5 level
2.3.5 External isolation devices for PV array
For Australia and New Zealand the PV SWITCH is not integrated. An external isolation device for
PV array ports is needed. The external isolation device shall conforms to the requirements
AS/NZS 4777.1
External isolation device for PV array table
Manufacturer
Model
PROJOY Electric Co., Ltd
PEDS100-EL40R-4(4MC4)