7.7.1.4.
Report off-hook time longer than
This option is being used if in configuration “PSTN line –
PX200NB
–
Alarm Control
Panel” there are not other telecommunication devices. If such device will be connected
and telephone number will be dialled (and a call will follow) after expiry defined time
limit (counted since conclusion of last digit dialling) the communicator sends a
message. This operation prevents unauthorised installation of additional devices.
7.7.1.5.
Report when intervals between dialled digits of phone are
longer than
This option is being used if in configuration “PSTN line –
LX30B
–
Alarm Control
Panel” there
are not other telecommunication devices. If such device will be
connected and telephone number will be dialled (and a call will follow) after expiry
defined time limit (counted since conclusion of last digit dialling) the communicator
sends a message. This operation prevents unauthorised installation of additional
devices.
7.7.1.6.
General dialtone
Some alarm control panels require that during a receiver picking up a tone of
dialling was actuated. To enable cooperation with a communicator it is possible to
make a communicator to generate such tone.
7.7.1.7.
Detect off-hook after
The default value for the delay detection off-hook is 100ms. You can define your
own delay value by choosing option "After" and giving the number in milliseconds.
7.7.2.
DTFM phone numbers
–
First and Second number
To provide for proper cooperation between a communicator and a control panel in
DTMF mode determination of some parameters is required. The below described
functions are analogous to the both telephone numbers that may be saved in the
device memory.
7.7.2.1.
DTFM phone number
This is a number that has been saved in memory of an alarm control panel. If the
panel is to transmit information on an event it shall dialled this number.
Transmission of this information via LTE/HSPA+ will be possible if this number will
be identical as a number entered into the communicator.
7.7.2.2.
Handshake delay
This defines time after which a communicator generates confirmation to an alarm
control panel for correct phone number dial. Default setting is 2.0 sec. European
Standard determines this value at 0.5 to 12.5 sec.
7.7.2.3.
Protocol
Select protocol of data transmission used by an alarm control panel and that is
acceptable for monitoring station. Available options: ContactID and SIA.