![EBS PX200NB Installation And Programming Manual Download Page 8](http://html1.mh-extra.com/html/ebs/px200nb/px200nb_installation-and-programming-manual_3806489008.webp)
PX200NB
–
Manual
Page 8 / 57
-
PCB
(without
casing)
Power
consumption DC
(AKU)
(average / max)
60mA/110mA@13,8VDC*
* Measured with full charged battery
Power
consumption AC
(average / max)
130mA/239mA
@18V
AC
*
* Measured with full charged battery
Power
supply
parameters
- PCB
(with casing
and EBS transformer)
Voltage supply 230V
AC
(acceptable: 190-250V
AC
)
Power
consumption
(average / max)
3W/20W @230V
AC
Charging module functions
- protection against reverse battery connection
- AC failure signalization
- low battery/no battery signalization
- protection against short circuit battery output
- polymer fuse
Backup battery connection
YES, lead-acid 12V
Battery charging current
max. 220mA
Threshold of signaling low AC
voltage (at secondary / at
primary)
13.5V
AC
/ 160V
AC
(with EBS transformer)
Threshold of signaling low battery
voltage
11V
DC
Dimension
PCB: 146 x 73 x 35 mm
Working temperature
-
10ºC … +55ºC
Working humidity
5% … 93%
Standards
CE