3. Installation
3.1 Installation position
3.1.3 Temperatures
The environmental ambient conditions for operation must not exceed the specified
values:
Ambient climatic conditions
Air pressure (in operation)
795 - 1080 hPa
max. 2000 m above sea level
Temperature
Operation
if using natural convection
± 0 – +45 °C (+32 – +113 °F) [System with SD- or mSATA memory]
± 5 – +45 °C (+41 – +113 °F) [System with HDD]
Storage / Transport
-20 – + 60 °C (-4 – +140 °F)
Humidity
Relative humidity 20 - 85 %, no condensation
Condensation
non-condensing
Ambient air
Free of corrosive gases
3.1.4 Aeration and de-aeration
l
Do not block the ventilation openings when mounting the XP-504:
They are designed to allow air to circulate in order to cool the device.
l
The XP-504 uses natural convection-based passive cooling, i.e., it does not use
fans.
l
The heat from the CPU and the power semiconductors in the power supply unit is
brought together through a heat spreader and then dispersed into the surrounding
air through the cooling fins on the housing.
Figure 5: Aeration and de-aeration
l
Make sure that there will be enough volume for air changes inside the control cab-
inet, etc.
The specified clearance around the Panel PC is: a, b ≧ 50 mm (1.97"), c ≧ 20 mm
(0.79")
XP-504
08/2021 MN048028EN Eaton.com
34
Summary of Contents for XP-504
Page 1: ...Manual 08 2021 MN048028EN XP 504 manual...
Page 4: ......
Page 14: ...0 1 About this documentation 15 XP 504 08 2021 MN048028EN Eaton com...
Page 62: ...5 Commissioning 5 2 Running the XP 504 63 XP 504 08 2021 MN048028EN Eaton com...
Page 66: ...6 Operation 6 2 Handling terminal 67 XP 504 08 2021 MN048028EN Eaton com...
Page 74: ...7 Operating system 7 2 Windows 10 Enterprise LTSC 75 XP 504 08 2021 MN048028EN Eaton com...
Page 76: ...8 Faults 77 XP 504 08 2021 MN048028EN Eaton com...
Page 94: ...Appendix A 2 Further usage information 95 XP 504 08 2021 MN048028EN Eaton com...