87
© 2017 Eaton. All rights reserved
2018.12.12
MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly
|
Service Procedures
TRSM0940
1
8
.
Remove the Range Synchronizer Assembly from the
Output Shaft
Note:
For disassembly and assembly of the Syn-
crhonizer, please refer to the “How to disassemble the
Sychronizer Assembly” section.
19.
Using a soft bar and maul, drive the Output Shaft for-
ward and through the Rear Bearing Assembly.
20.
Remove the six cap screws that fasten the Output Shaft
bearing cover to the Auxiliary Section.
21.
Remove the Output Shaft bearing cover.
22.
Inspect the Rear Bearing Cover oil seal for damage.
Remove if damage is found.