2019.07.11
© 2017 Eaton. All rights reserved
118
TRSM0940
Service Procedures
|
MHP/MXP/VHP/VXP Auxiliary Countershaft Installation
Auxiliary Section Installation
1.
Attach the Auxiliary Section lifting bracket to the top of
the Auxiliary Case.
2.
Position a new Auxiliary Case Gasket on the mounting
surface of the Main Case.
3.
Install the Auxiliary Case Assembly onto the transmis-
sion Main Case dowel pins. Using the Output Shaft,
wiggle the auxiliary case forward until it is as far for-
ward as possible. Remove the auxiliary section lifting
bracket.