2018.12.12
© 2017 Eaton. All rights reserved
146
TRSM0940
Service Procedures
|
Main Case Disassembly and Lubrication Tube Removal
23.
Using a 15/16” socket, remove the retaining bolt of the
lower Counter Shaft Front Bearing.
24.
Using a soft maul with hand guard, strike the case to
the right of the front lower Counter Shaft Bearing to
remove it from the bore.
Main Drive Gear and Input Shaft Removal
1.
Using the K-Line tools Input Bearing Puller, remove the
Input Shaft Bearing.
Note:
Input Shaft may also be driven through the bear-
ing using a soft hand maul.
2.
With the upper Counter Shaft still pushed as far toward
the case as possible, remove the Input Shaft, Main
Drive Gear and spacer as an assembly.
Summary of Contents for UltraShift PLUS FM-14E310B-LAS
Page 2: ...1 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Page 4: ......
Page 5: ...2019 07 11 2017 Eaton All rights reserved 4 TRSM0970 General Information ...
Page 6: ...5 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Page 7: ...2019 07 11 2017 Eaton All rights reserved 6 TRSM0970 General Information ...
Page 8: ...7 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Page 9: ...2019 07 11 2017 Eaton All rights reserved 8 TRSM0970 General Information ...
Page 10: ...9 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...