63
© 2017 Eaton. All rights reserved
2018.12.12
VCS/VMS Auxiliary Section Assembly and Installation
|
Service Procedures
TRSM0940
Auxiliary Countershaft Assembly and Timing
1.
For timing purposes, identify and mark with a highly
visible paint pen the two (2) teeth on each countershaft
that are identified with a “0” on the shaft. Use a straight
edge to line up the marked teeth with the teeth on the
remaining two (2) countershaft gears. Paint these
teeth.
2.
Position the two Auxiliary Countershaft assemblies on
a clean flat surface. Position the shafts so that the
painted timing teeth are facing inward towards each
other.
Note:
To ease in the assembly and timing procedure.
Use a fixture similar to the one outlined at the begin-
ning of the section.
3.
Install the assembled Auxiliary Mainshaft Assembly
between the countershafts and match the timing
marks.
Summary of Contents for UltraShift PLUS FM-14E310B-LAS
Page 2: ...1 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Page 4: ......
Page 5: ...2019 07 11 2017 Eaton All rights reserved 4 TRSM0970 General Information ...
Page 6: ...5 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Page 7: ...2019 07 11 2017 Eaton All rights reserved 6 TRSM0970 General Information ...
Page 8: ...7 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Page 9: ...2019 07 11 2017 Eaton All rights reserved 8 TRSM0970 General Information ...
Page 10: ...9 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...