49
© 2017 Eaton. All rights reserved
2018.12.12
VCS/VMS Auxiliary Section Removal and Disassembly
|
Service Procedures
TRSM0940
5.
Loosen the 1 1/2” nut retainer on the Output Shaft. Do
not remove the nut.
Note:
To prevent the counter shafts from turning, place
a shop rag or equivalent between the splitter gear and
one counter shaft.
6.
Using a soft bar and maul, drive the Output Shaft for-
ward far enough to partially unseat the bearing.
7.
Support the Auxiliary Countershaft and remove the
strap from the rear of the Auxiliary Case Housing
8
.
As the counter shaft straps are removed, the Counter
Shaft can fall!
9.
Repeat process to remove 2nd Auxiliary Counter Shaft.
10.
Remove the Auxiliary Counter Shaft Bearing Races
from their bores.