Transmission appearance may differ, procedure is the same.
9
External Parts
H/45-4
H/45-3
H/45-2
H/45-1
Air System
How to Install the Air Supply Hoses for LO and HI Range
Special Instructions
Make sure air hoses are not damaged.
Install the air hoses at their proper locations.
All externally threaded
1
⁄
4
" air fittings that are not coated
with pre-applied thread sealant must be coated with
Eaton sealing material #71209 or equivalent for at least
3 complete and consecutive threads.
For the
1
⁄
4
" I.D. air hoses, install the fixed nut end first.
To install the hoses, the air filter/regulator must be in
position.
Special Tools
Typical service mechanic tools
To Install
1.
If previously removed, install new air supply
fittings. Tighten to 7-10 Lb
f
·ft of torque.
2.
Connect one air supply hose end to the range
cylinder HI range supply port. Tighten to 7-10
Lb
f
·ft of torque.
3.
Connect the other end to the slave valve HI range
supply port. Tighten to 7-10 Lb
f
·ft of torque.
4.
Connect one air supply hose end to the range
cylinder LO range supply port. Tighten to 7-10
Lb
f
·ft of torque.
5.
Connect the other end to the slave valve LO range
supply port.
Final Check
Make sure air lines are not kinked.
2
3
4
5