XS series operating manual
XS user manual v0.55
- 66 -
ANY PARAMETER MODIFICATION IS AUTOMATICALLY STORED IN THE MEMORY
Expert mode parameters only
[expert]
As explained before, the expert mode gives more controls to the unit to adapt the behavior of the unit
regarding the user’s need.
Breakdown detection mode selection during the ramps
Fig 8.13
It is possible to select a breakdown detection mode specifically for the ramps.
The ramps parameters are valid for the rising and falling ramps together.
As mentioned before, the breakdown detection modes are :
I, IMAX+
I, IMAX, OFF,
FIMAX+
I, FIMAX
WARNING
IMAX and IMAX+
I modes involve that the current display is actived and the rising or the
falling times are greater or equal to 2s