4 Accessories
4.7 Device-specific accessories for devices with an IP20 degree of protection
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives
05/21 MN040058EN
www.eaton.com
103
Figure 71: Block diagram DXC-EXT-2RO1AO
→
For detailed instructions on how to install the module, please
refer to instruction leaflet IL04012014Z.
NOTICE
Internal relay K1 is connected to the expansion module,
meaning it can only conduct a relatively low current (
≦
1 A).
DANGER
Dangerous voltage!
Expansion module DXC-EXT-2RO1AO must not be placed into
operation until all mounting and installation work has been
completed (plugged in and connected to the DC1-S variable
frequency drive’s control signal terminals). Any other use will be
considered to be an inappropriate use.
2
DI1
3
DI2
4
DI3
1
5
+10 V
< 20 mA
6
7
0 V
0 V
8
9
10
11
12
13
1
DC1
2
3
4
5
6
8
9
10
11
P-18 = 1
READY
7
AI1
0 ... +10 V
AO1
0 ... +10 V/
20 mA
+24 V, <100 mA
f-Soll
f-Out
K1
K2
250 V AC/220 V DC, 1 A
4.7 kΩ
+
FWD
→
Depending on the type of load, we recommend the use of a
suppressor circuit when using the relay outputs (
Summary of Contents for PowerXL