31
XCHARGEIN MOBILITY INSTALLATION MANUAL
MN191005EN April 2021 www.eaton.com
00
Title
Register
Address
Always or
optional
R/W
Description
40007
06
Always
R/W
Status:
0 = Free
1 = Charging
2 = VehicleNotConnected
3 = VehicleWait
4 = VehicleNoFan
5 = BreakerDown
6 = ChargingError
7 = Paused
8 = DoorOpened
9 = Starting
10 = SessionTimeout
11 = OutOfCredit
12 = LockError
13 = OverCurrentError
14 = Booked
15 = NotResponding
40008
07
Always
R
Charge status:
0 = Unknown
1 = WaitEnabled
2 = Mode1_On
3 = Mode1_LockError
4 = Mode3_A
5 = Mode3_B_no_pwm
6 = Mode3_B_pwm
7 = Mode3_C
8 = Mode3_D
9 = Mode3_CD_to_B
10 = Mode3_E
11 = Mode3_F
12 = Mode3_PP_Error
13 = Mode3_Lock_Error
14 = Mode3_Ventilation_Error
40009
08
Always
R
Can be regulated:
0 = The charger cannot be regulated
1 = The charger can accept current regulation command
40010
09
Optional
R/W
Regulated current:
Controls how many amps the charger can deliver to
the vehicle in 100 mA.
Example: 145 = 14.5 A
40011
10
Optional
R
Maximum current:
Maximum current in 100 mA that the charging
station can deliver.
Example: 160 = 16 A
40012
11
Optional
R
Minimum allowed regulated current:
Minimum current in 100 mA
that the charging station should deliver (generally > 6 A). Below this level,
the charge will be stopped.
Example: 60 = 6 A
40013
12
Optional
R
Maximum allowed regulated current:
Maximum current in
100 mA that the charging station should deliver. Generally same value
as maximum current.
Example: 160 = 16 A
40014
13
Optional
R
Can provide energy consumption:
0 = No
1 = Yes, absolute value
2 = Yes, relative value (manually reset with 0x06 register)