2
GREEN MOTION DC 22 EV CHARGER INSTALLATION MANUAL
MN192004EN November 2022 www.eaton.com
00 Title
1.1 Field of applications
This installation manual is intended for professional installers. It describes how to securely install and commission the
Eaton Green Motion DC 22 EV charger:
Table 1. Green Motion DC 22 EV charger overview
Powe
r inp
ut
Input voltage AC
3 x 400 V 50 Hz
Nominal input current AC
3 x 32 A (22 kW)
Power factor
> 0.99
Phase
3 phase
Power output
Nominal output power
22 kW
Output voltage for the DC range
50 V - 500 V
Output current DC at nominal power 22 kW
55 A
Output type
- CCS 2 (default)
- CCS 2 and CHAdeMO (optional)
Efficiency
≤ 96 %
Simultaneous charging
1
Options
Cable
CHAdeMO
Floor-mounted
Floor-mounted with a pedestal
Network interface
3G/4G
Software licenses
Eaton Scan & Charge
Eaton Charging network manager
Warranty
Warranty
2 years
1.2 Symbols used in this manual
An electric shock can be fatal.
Avoid touching internal or external parts normally live while the system is powered on.
Read the instructions. These instructions are intended for professional installers. A professional installer must
be an expert in the field and is therefore responsible for commissioning the system in accordance with the
manufacturer’s instructions and local legislation.
Imminent dangers causing serious injuries. Danger of death.
Hazardous behaviors that could cause serious injuries.
Hazardous behaviors that could cause death.
Behaviors that could cause minor injuries to people or minor damages to things.