15
GREEN MOTION DC 22 EV CHARGER INSTALLATION MANUAL
MN192004EN November 2022 www.eaton.com
00
Title
Tag
Description
1
Green Motion DC 22 EV charger
2
Floor
3
Plug holder
5.2.2 Mounting on the wall
The unit should be fixed 1000 mm above ground level, for optimal accessibility. See Figure 8.
Keep at least 300 mm of free space from the left and right sides of the unit to allow for adequate air circulation.
The power input electrical cable and the internet connection cable are inserted underneath or from the bottom side of
the EV charger. See Section 6.2 for details.
Please note that the appropriate types of plastic plugs and screws must be selected by professional and
qualified personnel, based on the following considerations:
•
the location of installation, and
•
the type of the wall on which the system is to be mounted.
•
Recommended screws:
•
stainless steel Ø6 x 50 mm (min.)
In case of obstacles such as snow or similar, take precautions to keep at least 300 mm of free space from
the left and right sides of the unit to allow for adequate air circulation.
Figure 8. Green Motion DC 22 EV charger with installation distances
RFID
300 mm
(11.81 inch)
300 mm
(11.81 inch)
1000 mm (39.4 inch)
1000 mm (39.4 inch)
1600 mm (63 inch)
3
1
3
2