4. Construction and Function
MANUAL CEAG AUtoMAtiC tEst systEM At-s
+
40071860177 (C) December 2016 www.ceag.de
** Loopresistor
* Terminal without function
Klemmen
F3 Fernanzeige
Klemmen
2,5 mm²
starr/flexibel
Klemmen
AT-S+
Terminals
F3 Module
Terminals
2,5 mm²
starr/flexibel
Terminals
AT-S+
C0
C0
12
12
12
14
12
14
22
22
22
24
22
24
**
32
**
32
32
34
32
34
S1
S1
S1
S1
S2
S2
S2
S2
+24V
+24V
+24V
+24V
*
-24V
*
-24V
Klemmen
F3 Fernanzeige
Klemmen
2,5 mm²
starr/flexibel
Klemmen
AT-S+
Terminals
F3 Module
Terminals
2,5 mm²
starr/flexibel
Terminals
AT-S+
C0
C0
12
12
12
14
12
14
22
22
22
24
22
24
32
32
32
34
32
34
S1
S1
S1
S1
S2
S2
S2
S2
+24V
+24V
+24V
+24V
-24V
-24V
F3 Fernanzeige Wandmontage
F3 Module Wallmounting
Connecting F3 Module to AT-S+
F3 Fernanzeige UP-Montage
F3 Fernanzeige UP-Montage - F3 Module UP-Mounting
Connecting F3 Module to AT-S+
Anschluss F3 Fernanzeige an AT-S+
Anschluss F3 Fernanzeige an AT-S+
R=1K
Ω
R=1K
Ω
Klemmen
F3 Fernanzeige
Klemmen
2,5 mm²
starr/flexibel
Klemmen
AT-S+
Terminals
F3 Module
Terminals
2,5 mm²
starr/flexibel
Terminals
AT-S+
C0
C0
12
12
12
14
12
14
22
22
22
24
22
24
**
32
**
32
32
34
32
34
S1
S1
S1
S1
S2
S2
S2
S2
+24V
+24V
+24V
+24V
*
-24V
*
-24V
Klemmen
F3 Fernanzeige
Klemmen
2,5 mm²
starr/flexibel
Klemmen
AT-S+
Terminals
F3 Module
Terminals
2,5 mm²
starr/flexibel
Terminals
AT-S+
C0
C0
12
12
12
14
12
14
22
22
22
24
22
24
32
32
32
34
32
34
S1
S1
S1
S1
S2
S2
S2
S2
+24V
+24V
+24V
+24V
-24V
-24V
F3 Fernanzeige Wandmontage
F3 Module Wallmounting
Connecting F3 Module to AT-S+
F3 Fernanzeige UP-Montage
F3 Fernanzeige UP-Montage - F3 Module UP-Mounting
Connecting F3 Module to AT-S+
Anschluss F3 Fernanzeige an AT-S+
Anschluss F3 Fernanzeige an AT-S+
R=1K
Ω
R=1K
Ω
Switch for loop
resistance
left: ZB-S / AT-S
+
right: ZB 96
CG 2000
View on the F3 module
after opening the front
panel. Switch setting
on the left side for
AT-S
+
/ZB-S/CG2000 system.
4.4.4 F3 remote indication
Connection of a remote switch
Connections are made as per figure (single-line diagram)
as well as field installation diagrams and drawings.
The CEAG F3 remote switch is powered via the 24-V volt-
age supply system of CEAG sytems.
ATTENTION!
Do not use an external 24-V voltage supply!
NOTE
•
Observe national rules and regulations governing the
indicating and signalling behavior when using a remote
switch or a remote indicator for emergency lighting
systems.
•
Observe the instructions in the Technical Documenta-
tion as provided by the manufacturer of the CEAG F3
remote indicator.
Connections F3 Modul
Switch for loop resistance
The F3-remote indicating unit contains a switch for loop
resistance. The right figure shows the printed board which
includes a marking stating the switch settings depending
on the system.