Receipt/Unpacking
C440/XTOE Electronic Overload Relay, DeviceNet
MN04210002E—March 2011 www.eaton.com
9
Receipt/Unpacking
WARNING
Do not service with voltage applied—Lock-out Tags.
General
Upon receipt of the unit, verify that the catalog number and
unit options stated on the shipping container match those
stated on the order/purchase form.
Inspect the equipment upon delivery. Report any crate or
carton damage to the carrier prior to accepting the delivery.
Have this information noted on the freight bill. Eaton is not
responsible for damage incurred in shipping.
Unpacking
Remove all packing material from the unit. Check the unit for
any signs of shipping damage. If damage is found after
unpacking, report it to the freight company. Retain the
packaging materials for carrier to review.
Verify that the unit’s catalog number and options match
those stated on the order/purchase form.
Storage
It is recommended that the unit be stored in its original
shipping box/crate until it is to be installed.
The unit should be stored in a location where:
●
The ambient temperature is –40° to 85°C
●
The relative humidity is 5–95%, non-condensing
●
The environment is dry, clean and non-corrosive
●
The unit will not be subjected to high shock or vibration
conditions
Mounting
The expansion module (C440-XCOM) needs to be wired to
the C440/XTOE electronic overload relay as shown in the
figure below.
Expansion Module Wiring
1.
Remove dust cover.
2.
Insert C440-XCOM module until detent is reached.
3.
Pull terminal block from module.
4.
Assure module was retained by overload.
5.
Wire per
Page 10
, C440 to C440-COM-ADP Wiring.
Dust Cover
Expansion
Module
(C440-XCOM)
Insert Screwdriver
to Remove Module
C440 DeviceNet.book Page 9 Friday, March 25, 2011 10:41 AM
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616