Plumbing
5B6331 – 01JUN99
49
[6] Remove the 2 SCREWS from the FIXER
THERMOWELL.
[7] Install 2 CLAMPS TL-2170 on the 2 HOSES to the
FIXER THERMOWELL.
[8] Move the FIXER THERMOWELL for access to the
FIXER HEATER.
[9] Disconnect the CONNECTOR P/J19.
[10] Remove the FIXER HEATER from the FIXER
THERMOWELL.
[11] Apply only SEALANT TL-3230 on the threads of
the FIXER HEATER when you install the FIXER
HEATER in the FIXER THERMOWELL.
Note
• A different SEALANT might cause damage to the
plastic in the THERMOWELL. See the instructions
packed with the SEALANT.
• The HEATER LOCATOR must be in the correct
position.
• Do not overtighten the parts when you install the
FIXER HEATER.
[12] Check that the internal HEATER LOCATOR is in
the correct position inside the FIXER
THERMOWELL.
[13] Assemble the PROCESSOR.
[14] Check for leakage at the FIXER THERMOWELL.
H150_0126CA
2 SCREWS
HEATER
THERMOWELL
FIXER
FIXER
CONNECTOR P/J 19
TL-2170
CLAMP
H150_0126CCA
13.9 0.25 cm
(5.5 0.1 in)
+
-
+
-
8.38 0.25 cm
(3.3 0.1 in)
+
-
+
-
H104_0444BA
HEATER
LOCATOR
LOCATOR
HEATER
H104_0444BCA