ADJUSTMENTS AND REPLACEMENTS
54
01JUN99 – 5B6331
Removing the POPPET VALVES for the REPLENISHMENT PUMPS
Important
• Use this procedure for removing the POPPET VALVES in either the FIXER or the DEVELOPER
REPLENISHMENT PUMP.
• Observe the direction of the POPPET VALVES before you remove them.
• Removing the REPLENISHMENT PUMP may be necessary for easier access to the POPPET VALVES.
• Check that the POPPET VALVES and O-RINGS seat correctly.
Warning
Dangerous Voltage
[1] De-energize the PROCESSOR.
[2] Lift the TOP COVER.
[3] Remove the NON-DRIVE SIDE PANEL.
[4] Install 2 CLAMPS TL-2170 on the 2 HOSES at the REPLENISHMENT PUMP.
[5] Loosen the HOSE CLAMPS and remove the 2 HOSES from the REPLENISHMENT PUMP.
[6] Remove the 2 FITTINGS from the VALVE BODY.
[7] Remove the 2 O-RINGS and the 2 POPPET VALVES from the VALVE BODY.
[8] Install all new POPPET VALVES and O-RINGS in the VALVE BODY.
[9] Install the REPLENISHMENT PUMP and assemble the PROCESSOR.
H150_0123BA
H150_0123BCA
DEVELOPER
FIXER
PUMP
REPLENISHMENT
REPLENISHMENT
PUMP
2 FITTINGS
2 O-RINGS
VALVE
BODY
2 POPPET VALVES