31
9.
Locate the gas-supply stub inside the fireplace and
remove the cap, if attached.
CAUTION:
When removing the cap, make sure the stub
does not turn, loosening the connection inside the wall.
10.
Be sure gas to the fireplace is off. Remove the
adapter connected to the flex connector (pre-installed on
the burner system). Attach the adapter to the gas-supply
stub using a pipe compound resistant to all gasses.
Tighten securely. Then attach the open end of the flex
connector to the adapter. Tighten securely.
(Figure 44)
11.
LEAK TEST: Turn on the fireplace gas supply, and test
at all connections for leaks using the appropriate soapy
water solution. If bubbles appear, a leak is present. Turn
off the gas and tighten at all connections. Repeat until
no leaks are present. If a leak persists, turn off the gas
supply and contact the local gas company or dealer.
NEVER USE A FLAME TO CHECK FOR LEAKS.
12.
LIGHTING TEST: Prior to proceeding with installation,
perform a lighting test (see lighting instructions for
lighting your burner). Allow the unit to completely cool
after testing.
13.
Spread the supplied lava granules on the floor of
the fireplace, around the front and sides of the burner
system.
(Figure 45)
The lava granules may be placed
around the switch box. Leave the front of the switch box
clear for control access.
14.
Repeat this process for the supplied lava coals (on
top of the already placed lava granules).
NOTE:
DO NOT place any lava media on the burner
system, or behind it.
15.
Spread the supplied wood chunks on the lava media,
around the front and sides of the burner system. Leave
the front of the switch box clear for control access.
NOTE:
DO NOT place any wood chunks on the burner
system, or behind it.
LOG LOCATORS
(if applicable)
ISO-IBV 46" models include a set of log locators. They
are used to support the front logs of select log sets. If
the log set chosen includes log locator install details (in
placement instructions), install accordingly. If not, discard
the log supports.
Earthcore Industries
08/2017
BVETTO B-Vent Gas Fireplace
ISOKERN Gas Log Set - Burner Installation
Place lava media
Connect gas supply
Flex connector
Adapter
Gas supply stub
FIGURE 44
FIGURE 45
IMPORTANT:
For all valves, the air MUST be purged from
the gas line before the pilot will light and burn properly.
The time needed to purge will depend on the length of
the gas line to the unit and the amount of time since the
unit or gas line was last used. It may take several minutes
before all the air is purged and the pilot will light and
burn properly. Reference the LIGHTING INSTRUCTIONS
section in this manual.