background image

Chapter 1. Gratitude

1

Thank you for purchasing an EAGLE   ECON series Digital Weighing 

Scale. The ECON series models are high performance and economic 
digital Weighing Scales that we confidently  recommend based on over 
97 years of Weighing Scale manufacturer. While these models are of 
course capable of fast and accurate weighing, the ECON Series models 
all use the High Precision Load Cells and highly reliable electronic boards 
that EAGLE started using for Digital Weighing Scale in 1976, and the 
ECON  Series  models  use  our  unique,  newly  developed  and  robust 
product range, improving the reliability of the scales still further.

The  new  ECON  series  Scales  also  feature  operation  keys  for  four 
directions, improving convenience and making the scales easier to use. 
ECON  Series  Scales  have  Counting  Function,  Liter  Conversion, 
Password Protected unit conversion, Weight Accumulation Function up 
to 999999, Selectable display speed, Auto Tare, Peak Hold, Auto Sleep, 
Zero Locking counts and Stable time setting. These Scales also feature a 
variety of other functions that make it more convenient for customers to 
use them for their own   applications, including the PC communication 
function,  which  enables  measuring  results  to  be  transferred  to  a  PC 
without installing any software. To ensure that you can make full use of 
the performance and functions of your ECON series balance, read this 
instruction manual carefully and use the scale correctly in accordance 
with the directions in the manual. When you have finished reading the 
manual, keep it in a safe place together with the scale so that you can 
refer to it at any time.

For information on the following points, please contact our 

EAGLE representative.
Product warranty and After Sales service

PROVIDER OF LIFE STYLE & INDUSTRIAL SCALES

Survey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, 

Fax : + 91 - 20 - 30418126. Email : [email protected]

Summary of Contents for ECON Series

Page 1: ...Digital Weighing Scale ECON Series USER MANUAL...

Page 2: ...30418100 110 Fax 91 20 30418126 Email sales egkantawalla com INDEX 1 Gratitude 2 Unpacking 3 Installation Procedure 2 Technical Data of Scale 3 Connections 4 Key Operation 5 Scale Functions 6 User Pa...

Page 3: ...nversion Weight Accumulation Function up to 999999 Selectable display speed Auto Tare Peak Hold Auto Sleep Zero Locking counts and Stable time setting These Scales also feature a variety of other func...

Page 4: ...Red Pin 2 Supply Black Pin 3 Signal Green Pin 4 Signal White Pin 5 Shield RS 232 Cable Wiring Db9 Pin Female Connector Scale End DB9 Pin Female Connector Scale End GND Pin 5 Pin 5 GND Tx Pin 3 Pin 2...

Page 5: ...can count the similar items on the scale The scale have 6 fixed sample sizes they are 10 20 50 100 200 and 500 pieces When the Func Key is pressed the display alternates between the following 1 S 0 th...

Page 6: ...r of samples on the scale as 10 To Recall Previous Counting Mode 1 Press Func key the display will show S 0 2 Press Func key again to change the option and select S Cnt 3 Press M key for the confirmat...

Page 7: ...ated weight three times and then back to weighing mode To clear the accumulated weight Press M key in zero mode sale display will show Add xxx for 1 sec and then flashes accumulated weight During the...

Page 8: ...tr 01 tr 02 tr 13 b rAt b 1200 b 2400 b 4800 b 9600 OUt N d OUt OUt G OUt t TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO TARE ZERO M M M M Chapter 8 User Parameter Setting Mod...

Page 9: ...ro function Peak Hold Function Auto Sleep Time Zero Lock Counts Stable Time Auto Tare function Stable Time Pn Zro Zro y Zro n P HLd HLd n HLd y A SLP SLP 00 to 99 Zr Loc Loc 00 to 99 Stb t Stb 2 Stb 1...

Page 10: ...ssing FUNC key it will back to display Speed Selection If without selection escaped out then scale will work on previously set speed 2 RS 232 Data Format tr 232 The scale have 13 different Data format...

Page 11: ...Data Format d Scale always shows previously set Data Format Using TARE ZERO keys select from tr 01 to tr 13 e Press M key to confirm the selection f Use FUNC key to escape from selection Note Pressing...

Page 12: ...e immediately removed only if scale goes in negative value e g Acontainer is kept on the scale and is automaticallyTARE the weight once now material is filled in the container i e scale is showing wei...

Page 13: ...ly set Power ON Zero Using TARE ZERO keys select trE y or trE n e Press M key to confirm the selection f Use FUNC key to escape from selection Note Pressing FUNC key it should back to Power ON Zero If...

Page 14: ...o SleepTime c Press M key to selectAutoTare d Scale always shows previously set Auto Sleep Time Using TARE for DECREASE ZERO for INCREASE and N G key for SHIFT can change the Sleep time e Press M key...

Page 15: ...conversion factor maximum value allowed is 1 000 To setAuto SleepTime a Enter in to User Parameter Setting Mode b using TARE ZERO keys select Set Liter Factor c Press M key to enter Liter Factor d Sc...

Page 16: ...eys select from Stb 1 to Stb 3 e Press M key to confirm the selection f Use FUNC key to escape from selection Note Pressing FUNC key scale will go back to Stable Time If without selection escaped out...

Page 17: ...solvent e g benzene nitro class oil to clean the housing 5 Liquid or electricity conducting particles should not be poured into the scale 6 You should cut off power supply of scale and relevant devic...

Page 18: ...nt is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of EAGLE company This warranty does not cover equipment wh...

Page 19: ...le Top Scales Platform Scales Crane Scales Pallet Scale LifeStyle Scales Hanging Scales 12 PROVIDER OF LIFE STYLE INDUSTRIAL SCALES Survey No 28 1 Damodar Nagar Kharadi Pune 411014 Tel 91 20 30418100...

Reviews: