8
PROVIDER OF LIFE STYLE & INDUSTRIAL SCALES
Survey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110,
Fax : + 91 - 20 - 30418126. Email : [email protected]
[tr-13] - this mode of transmission is used to connect a scoreboard to
indicator.
PRINT Keys – Press [N/G] and [FUNC] keys simultaneously.
e.g. If my selected data transmission format is tr-01 then data will be
transmitted when print key is pressed on scale and in the format
(=002.000) weight only.
Note: Every time when weight is transmitted the starting character “=” is
always kept common for all modes and formats.
To set RS-232 Data Format:
a. Enter in to User Parameter Setting Mode
b. Using [TARE]& [ZERO] keys select RS-232 Data Format
c. Press [M] key to select Data Format
d. Scale always shows previously set Data Format. Using [TARE] &
[ZERO] keys select from tr-01 to tr-13
e. Press [M] key to confirm the selection
f. Use [FUNC] key to escape from selection
Note: Pressing [FUNC] key it will go back to Data Format. If without
selection escaped out then scale will work on previously set Data format.
3. Baud Rate Selection –
The scale have 4 baud rates and are user
selectable as explained below.
To set Baud Rate:
a. Enter in to User Parameter Setting Mode
b. Using [TARE] & [ZERO] keys select Baud Rate Selection
c. Press [M] key to select Baud Rate Selection parameter
d. Scale always shows previously set Baud Rate. Using [TARE] &
[ZERO] keys select from b-1200 to b-9600
e. Press [M] key to confirm the selection
f. Use [FUNC] key to escape from selection
Note: Pressing [FUNC] key it will go back to Baud Rate Selection. If
without selection escaped out then scale will work on previously set Baud
Rate.