9
PROVIDER OF LIFE STYLE & INDUSTRIAL SCALES
Survey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110,
Fax : + 91 - 20 - 30418126. Email : [email protected]
1. Display Speed Selection [d-SPd]-
The scale have 5 different
display update speeds. SPd-1 is the fastest and SPd-5 is the
slowest speed.
To set Display Speed:
a. Enter in to User Parameter Setting Mode showing Display Speed
Selection
b. Press [M] key to select display speed
c. Scale always shows previously set display speed. Using [TARE] &
[ZERO] key to select SPd-1 to SPd-5
d. Press [M] key to confirm the selection
e. Use [FUNC] key to escape from selection
Note: Pressing [FUNC] key it will back to display Speed Selection. If
without selection escaped out then scale will work on previously set
speed.
2. RS-232 Data Format [tr-232]-
The scale have 13 different Data
formats the way explained below.
Three modes of transmission and four formats of data explained in
following table. The command from computer will be Z, T and $
character.
Z Command – The scale should get ZEROD.
T Command – The scale should get TARED.
$ Command – The scale should send the weight data to PC
Transmission
Modes
Formats
Weight
Sign+
Weight
Unit
Sign+
Unit
On Pressing
COUNT Key
=002.000
[tr-01]
=+002.000
[tr-02]
=002.000kg
[tr-03]
=+002.000kg
[tr-04]
Continuous
Transmissio
n
=002.000
[tr-05]
=+002.000
[tr-06]
=002.000kg
[tr-07]
=+002.000kg
[tr-08]
On command ”$”
from computer
=002.000
[tr-09]
=+002.000
[tr-10]
=002.000kg
[tr-11]
=+002.000kg
[tr-12]