Model SRV930 Series Medium Capacity Counter Top Scale 
Operating and Service Manual - S/N 1132+ 
Part No.:  MANSRV930_141208 

 

Page 1 of 14 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

        

Copyright 

2014

 

S

Instruments, Inc. 

 
 

S

by 

S

 Instruments, Inc.

 

 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 

 

Operating and Service 

Manual 

Serial Numbers:  1132+  

 

Model SR

V930

 

Medium Capacity 

Counter Top Scale

 

Summary of Contents for SRV930

Page 1: ...30_141208 Page 1 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SInstruments Inc S by S Instruments Inc Operating and Service Manual Serial Numbers 1132 Model SRV930 Medium Capacity Counter Top Scale ...

Page 2: ...Inc TABLE OF CONTENTS TABLE OF FIGURES 2 PACKING CHECKLIST MODEL SRV930 3 ASSEMBLY 3 ACCESSORIES 3 SYSTEM DESCRIPTION AND INTENDED USE 4 MAINTENANCE AND CLEANING 4 STORAGE AND TRANSPORTATION 5 SPECIFICATIONS 6 BUTTON FUNCTIONS 7 BASIC SYSTEM OPERATION 8 BATTERY REPLACEMENT 8 CALIBRATION 10 TROUBLESHOOTING 11 WARRANTY 12 NOTES 13 TABLE OF FIGURES Figure 1 Battery Compartment Cover 3 Figure 2 Displa...

Page 3: ... check parts against the PACKING CHECKLIST If there are any missing or damaged parts please call the Service Hotline 1 800 654 6360 STEP 2 Figure 1 Turn scale over Slide open Battery Compartment Cover Insert supplied 9 volt battery See BATTERY REPLACEMENT instructions Slide Battery Compartment Cover closed Turn scale over STEP 3 Install End Caps over handrails ACCESSORIES DESCRIPTION QUANTITY SCAL...

Page 4: ...ht is displayed on a 4 digit LCD display INTENDED USE The SRV930 is designed for use as an animal weighing system for animals not exceeding 44 pounds Please read the following warnings to avoid injury to the animal or attendant MAINTENANCE and CLEANING The SRV930 scale s weighing surface is made from durable plastic Exercise caution when cleaning the display window as it is made of a clear plastic...

Page 5: ...RAGE If storing this equipment for periods longer than three 3 months remove the battery To maintain proper operation of this instrumentation storage and transport conditions should not vary outside the following conditions Ambient Temperature 41 F to 95 F 5 C to 35 C TRANSPORTATION To transport the SRV930 from one location to another within the office use the handles to lift and carry If moving f...

Page 6: ...RESOLUTION 0 02 lb 0 5 oz 0 01 kg AUTO POWER DOWN Adjustable to 120 180 240 300 seconds and OFF MEMORY While active freezes display data and stores it in memory LAST WEIGHT RECALL MEMORY button recalls last stored weight AVERAGING Automatic digital filter POWER SUPPLY One 1 9 volt battery or optional AC DC adaptor CALIBRATION Calibrated to manufacturing specifications OPERATING CONDITIONS Normal o...

Page 7: ...uments com Copyright 2014 SInstruments Inc TARE ON OFF Kg Lb MEMORY BUTTON FUNCTIONS The TARE ON OFF button is used to turn the scale on off to tare the weigh or to zero the display Holding the TARE ON OFF button for two seconds will manually shut down the scale The Kg Lb button is used to toggle between lb oz lb oz or kg The system is set in pounds The MEMORY button is used to recall the weight o...

Page 8: ...s and the scale is shut down the weight mode will be in kilograms when the scale is turned back on TARE The tare function is used to subtract any additional items example receptacle from the patient s Net weight MEMORY Press the MEMORY button to store the last weight for recall if needed To view the last stored weight in memory press the MEMORY button again to return to the original value NOTE MEM...

Page 9: ...s until the word END is displayed Press the MEMORY button to save your changes the display will return to normal mode BATTERY REPLACEMENT The low battery indicator will display on LCD display when battery s power is insufficient to operate the scale If available you can plug in the AC adaptor to continue operation STEP 1 While the tray is empty turn the scale over with the feet facing in the upwar...

Page 10: ...calibration mode STEP 4 Ensure scale is in kilograms mode STEP 5 Place 20 kg dead weight on the scale platform Display will show a span count between 2000 16000 STEP 6 Press TARE ON OFF button one 1 time Display will read CAL and then read 20 00 kg STEP 7 Remove the weight Display will read 0 00 Calibration is now complete Press the TARE ON OFF button to turn scale off Figure 4 Calibration Button ...

Page 11: ... total weight exceeds the maximum capacity of the scale removed weight from the surface Memory will not Zero Memory will hold the last stored weight until it is replaced with another stored weight It will never zero Memory will not store Memory will not store weight if weight is less than two 2 pounds or 0 9 kilograms For additional information or assistance phone our Service Hotline 1 800 654 636...

Page 12: ...R Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser upon delivery to Tra...

Page 13: ...le Operating and Service Manual S N 1132 Part No MANSRV930_141208 Page 13 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SInstruments Inc NOTES ...

Page 14: ...ual S N 1132 Part No MANSRV930_141208 Page 14 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SInstruments Inc S By SInstruments Inc Precision Technology in Perfect Balance ...