A8

-

35

Protection action 

selection 1

1823H

0000 2222

Led bit0: motor overload (err11) action 
selection
0: free stop, fault alarm
1: emergency stop, fault alarm 
2: only warning, converter continues to 
operate
Led bit1: input phase loss (err12) action 
selection
Same as Led bit0
Led bit2: output phase loss (err13) action 
selection
Same as Led bit0
Led bit3: external fault (err15) action 
select
Same as Led bit0

0

1824H

0000 3123

Led bit0: abnormal communication (err16) 
action selection
Same as p9-50 bits
Led bit1: encoder failure (err20) action 
selection
0: free stop, fault alarm
1: emergency stop, fault alarm
2: switch to VF, continue operation
Led bit2: function code reading and writing 
abnormal (err21) action selection
0: free stop, fault alarm
1: emergency stop, fault report
Led bit3: motor overheating (err25) action 
select
Same as Led bit0

A8

-

36

Protection action 

selection 2

0

0000

0002

"

Led bits: speed feedback error (err52) action 

selection
Same as P9-50 bits
Led tens: reserved
Led hundreds: reserved
Led thousands: reserved“

Only read

AC drive status

PU

-

00

2100H

AC drive 

fault type

PU

-

01

U00.3=1

2101H

Only read
BIT0=Runing           BIT1=0:fwd 1:rev     
BI02=ready            BIT3=fault         
BIT4=jog              BIT5=pre alarm       
BIT6=atuo tuning      BIT7-15=NC 

2 5

 -

26

 -

  F u n c t i o n C o d e T a b l e

EC670

 

EC670

 

  F u n c t i o n C o d e T a b l e

1825H

0000 2222

Led bit0: user defined fault 1 (err27) 
action selection
Same as p9-50 bits
Led bit0: user defined fault 2 (err28) 
action selection
Same place
Led bit0: power on time arrival (err29) 
action selection
Same place
Led bit0: load loss (err30) action selec-
tion                                 
0: emergency stop, fault alarm
1: emergency stop, fault alarm
2: directly jump to 7% of the rated fre-
quency of the motor to continue operation, 
and automatically return to the set fre-
quency operation if no load is dropped

A8

-

37

Protection action 

selection 3

0

1826H

A8

-

38

Protection action 

selection 4

0

0000 2222

Led bit0: loss of PID feedback during ope-
ration (err31) action selection
Same as P9-50 bits
Led bit1: excessive speed deviation (err42) 
action selection

1826H

A8

-

38

Protection action 

selection 4

0

Same as Led bit0
Led bit2: motor over speed (err43) action selec-
tion
Same as Led bit0
Led bit3: initial position error (err51) action 
selection
Same as Led bit0

1827H

A8

-

39

Protection action 

selection 5

0

U

 

Monitoring parameter group

Function 

Code

Parameter Name

Setting Range

Default

 

Address

Only read
Err00  -- ERROR_NONE                      
Err01  -- ERROR_INVERTER_UNIT             
Err02  -- ERROR_OC_ACC_SPEED              
Err03  -- ERROR_OC_DEC_SPEED              
Err04  -- ERROR_OC_CONST_SPEED            
Err05  -- ERROR_OV_ACC_SPEED              
Err06  -- ERROR_OV_DEC_SPEED              
Err07  -- ERROR_OV_CONST_SPEED            
Err08  -- ERROR_BUFFER_RES                
Err09  -- ERROR_UV                        
Err10 -- ERROR_OL_INVERTER               
Err11 -- ERROR_OL_MOTOR                  
Err12 -- ERROR_LOSE_PHASE_INPUT          
Err13 -- ERROR_LOSE_PHASE_OUTPUT         
Err14 -- ERROR_OT_IGBT   
Err15 -- ERROR_EXTERNAL                  
Err16 -- ERROR_COMM      
Err17 -- ERROR_CONTACTOR                 
Err18 -- ERROR_CURRENT_SAMPLE            
Err19 -- ERROR_TUNE      
Err20 -- ERROR_ENCODER1                  
Err21 -- ERROR_EEPROM    
Err22 -- ERROR_22                        
Err23 -- ERROR_MOTOR_SHORT_TO_GND        
Err24 -- ERROR_24        
Err25 -- ERROR_25                        
Err26 -- ERROR_RUN_TIME_OVER             
Err27 -- ERROR_USER_1    
Err28 -- ERROR_USER_2                    
Err29 -- ERROR_POWER_UP_TIME_OVER        
Err30 -- ERROR_LOSE_LOAD 

Summary of Contents for EC670

Page 1: ...sional AC Drive Manufacturer EC670 AC Drive for elevator Professional AC Drive Manufacturer ZHEJIANG EACN ELECTRONIC TECHNOLOGY CO LTD Address No 1 Jinhe Road Qinshan Street Haiyan County Jiaxing City...

Page 2: ...le 7 1 A0 Basic parameter group 7 2 A1 Start stop and frequency parameter group 7 3 A2 Terminal IO parameter group 7 4 A3 Communication parameter group 7 5 A4 UPS parameter group 7 6 A5 Motor paramete...

Page 3: ...pply is cut off but the indicator light of the mani pulator of AC drive is still on there is still high voltage in the AC drive which is very dangerous please do not touch the interior circuit and com...

Page 4: ...nce 22k 1 Input range DC 0V 10V 4mA 20mA decided by selection of P5 00 2 Impedance 22k voltage input 500 current input 1 Optocoupler coupling isolation compatible with dual polarity input 2 Impedance...

Page 5: ...he startup operation is performed on the rotating motor 7 A sudden load is added during acceleration 8 The AC drive model is of too small power class 1 The output circuit is grounded or short circuite...

Page 6: ...bnormal 2 The drive board is faulty 3 The lightening board is faulty 4 The main control board is faulty 1 Eliminate external faults 2 Seek technical support 3 Seek technical support 4 Seek technical s...

Page 7: ...ning 3 Set P9 40 and P9 41 correctly based on the actual situation 7 Function Code Table Function Code Table EC670 Faults and solutions EC670 9 10 A0 Basic parameter group Address Function Code Settin...

Page 8: ...S2 terminal function 1201H 3 0 56 0 No function 1 Forward RUN FWD 2 Reverse RUN REV 3 Three line control 4 Forward JOG FJOG 5 Reverse JOG RJOG A1 Start stop and frequency parameter group Setting Rang...

Page 9: ...00 1208H A2 03 S4 terminal function 16 1203H A2 04 S5 terminal function 17 1204H A2 05 S6 terminal function 18 1205H A2 06 S7 terminal function 19 1206H A2 07 S8 terminal function 53 1207H A2 09 S1 S4...

Page 10: ...s run freq lmt Ups direction check frequency delay 1 0 10 0 During the acceleration process of UPS mode startup the maximum value of forward torque is detected If the value is exceeded the direction o...

Page 11: ...5 12 Encoder type 150CH 0000 A5 13 Encoder pulses per revolution 150DH 1024 0 60000 A5 21 Vector control slip gain 30 200 For the speed sensorless vector control this parameter is used to adjust the s...

Page 12: ...adjustment proportional gain 2000 151AH A5 27 Excitation adjustment integral gain 1300 151BH A5 28 Torque adjustment proportional gain 2000 151CH A5 29 Torque adjustment integral gain 1300 151DH 0000...

Page 13: ...V_DEC_SPEED 7 ERROR_OV_CONST_SPEED 8 ERROR_BUFFER_RES 9 ERROR_UV 10 ERROR_OL_INVERTER 11 ERROR_OL_MOTOR A8 04 1804H Only read 1st fault type 21 22 Function Code Table EC670 EC670 Function Code Table A...

Page 14: ...is function is used to give a warning signal to the control system through y before the motor overload fault protection The early warning coefficient is used to determine the degree of early warning b...

Page 15: ...bit0 power on time arrival err29 action selection Same place Led bit0 load loss err30 action selec tion 0 emergency stop fault alarm 1 emergency stop fault alarm 2 directly jump to 7 of the rated fre...

Page 16: ...y read Ao1 output value PU 35 2123H Only read Ao2 output value PU 36 2124H Only read HDO output value PU 37 2125H Only read Reserved PU 38 2126H Only read Module temperature PU 39 2127H Only read Outp...

Page 17: ...e output Y3 Y4 YC Shielded twisted pair Close to AC drive ground terminal Coil Coil PLC Shielded twisted pair Close to AC drive ground terminal AC200V ACOV Coil Shielded twisted pair Close to AC drive...

Page 18: ...maximum input frequency of 50KHz 4 Port Y4 is restricted by function parameter P5 32 which can be used as high speed pulse input channel with maximum input frequency of 50KHz 1 2 Standard wiring diagr...

Reviews: