  F u n c t i o n C o d e T a b l e

EC670

 

EC670

 

  F u n c t i o n C o d e T a b l e

A2

-

14

A2

-

15

Y2 terminal 

function

Y3 terminal 

function

120EH

120FH

14:Software current limit exceeded
15:Torque limited
16:Motor overload pre-warning
17:AC drive overload pre-warning
18:Zero-speed running (no output at stop)
19:Acceleration runing
20:Deceleration runing
21:Dc breaking
22:PLC step complete
23:PLC cycle complete
24:Resv
25:Accumulative running time reached
26:Timing reached
27:Designated count value reached
28:Set count value reached
29:AI1 input limit exceeded
30:Module temperature reached
31:Fan runing
32:From com do1
33、From com do2
34:From com do3
35:From com do4
36:Output uvw contactor enable 
37:Mechanical brake contactor enable
38:Pre open door enable

36

5

A4

-

00

0000

0011

LED-Bits0:
0:Lift control disable
1:Lift control enable
LED-Bits1:
0:UPS active change direction mb disable
1:UPS active change direction mb enable
LED-Bits2:reserve
LED-Bits3:reserve

0110

1400H

Lift control 

mode

A2

-

16

Y4 terminal 

function

1210H

5

A3

 

Communication parameter group

Function 

Code

Parameter Name

Setting Range

Default

 

Address

A3

-

00

Address

1300H

1

247

1

A3

-

01

Baud rate sel

1301H

0

8

5

A3

-

02

Data format

1302H

0

5

3

A3

-

03

1303H

0

7

3

A3

-

04

Communication 

response delay

1304H

0

.

000

0.500

0.000s

A3

-

05

Communication 

response delay

1305H

0.1

100

.

0

1.0s

A3

-

06

Transmission 

response 

processing

1306H

0

1

0

A4

 

Holding brake and UPS parameter group

Function 

Code

Parameter Name

Setting Range

Default

 

Address

A4

-

01

0~10.0s
The maintenance time of detecting torque 
direction frequency during UPS mode startup 
acceleration

0~100%-hz
Operating frequency in UPS mode

1.0

6Hz

A4

-

05

1401H

1405H

Ups run 

freq lmt

Ups direction 

check frequency 

delay

1

.

0

10.0%

During the acceleration process of UPS mode 

startup, the maximum value of forward torque 

is detected. If the value is exceeded, the 

direction of operation will be switched

5.0%

A4

-

06

1406H

Ups dir 

check torque 

lmt

A4

-

07

0

.

05s

1407H

Ups dir check

refe torque 
filter time

0

.

01

1

.

00s

Current output torque is collected in normal 
operation mode for reference of direction 
identification when switching into UPS mode. 
This value is the filtering time when 
collecting torque.

1.0~10.0s
Acceleration time in UPS mode

3.0s

A4

-

02

1402H

Ups acc time

1.0~10.0s
Deceleration time in UPS mode

2.0s

A4

-

03

1403H

Ups dec time

1

.

00~20.00Hz

Refer to the maximum frequency

5.00Hz

A4

-

04

1404H

Ups dir 

check freq

A4

-

08

150%

1408H

Ups mode 

torque lmt

50

150

%

The maximum value of forward torque during 
UPS mode operation. When the value is 
exceeded, the output frequency will be 
reduced

A4

-

09

160V

1409H

Ups mode 

Uu val

50

100

%

-Voltage

100% = undervoltage value in 350vdc UPS 
mode

A4

-

10

/

140AH

Ups Torque 

record value

(-

150)

150

%

 only

 

read 

Output torque value collected in normal 
operation mode

A4

-

11

/

140BH

Ups direction 

record value

Only reay
Operation direction of acquisition in normal 
operation mode

A4

-

12

2.0s

140CH

Ups dir change 

dc break time

0

10.0

DC braking time when torque exceeds the 
maximum value of a4-09 forward torque 
during startup acceleration in UPS mode

A4

-

13

50%

140DH

Ups dir change 

dc break 

current

0

150%

DC braking current in reverse direction 
when torque exceeds a4-09 maximum forward 
torque during UPS mode startup acceleration

A5

 

Motor parameters and vector control parameters group

Function 

Code

Parameter Name

Setting Range

Default

 

Address

A5

-

00

0

1500H

Auto-tuning 

selection

0

3

In order to obtain better VF or vector con-
trol performance, it is necessary to tune 
the motor parameters, and the accuracy of 

Summary of Contents for EC670

Page 1: ...sional AC Drive Manufacturer EC670 AC Drive for elevator Professional AC Drive Manufacturer ZHEJIANG EACN ELECTRONIC TECHNOLOGY CO LTD Address No 1 Jinhe Road Qinshan Street Haiyan County Jiaxing City...

Page 2: ...le 7 1 A0 Basic parameter group 7 2 A1 Start stop and frequency parameter group 7 3 A2 Terminal IO parameter group 7 4 A3 Communication parameter group 7 5 A4 UPS parameter group 7 6 A5 Motor paramete...

Page 3: ...pply is cut off but the indicator light of the mani pulator of AC drive is still on there is still high voltage in the AC drive which is very dangerous please do not touch the interior circuit and com...

Page 4: ...nce 22k 1 Input range DC 0V 10V 4mA 20mA decided by selection of P5 00 2 Impedance 22k voltage input 500 current input 1 Optocoupler coupling isolation compatible with dual polarity input 2 Impedance...

Page 5: ...he startup operation is performed on the rotating motor 7 A sudden load is added during acceleration 8 The AC drive model is of too small power class 1 The output circuit is grounded or short circuite...

Page 6: ...bnormal 2 The drive board is faulty 3 The lightening board is faulty 4 The main control board is faulty 1 Eliminate external faults 2 Seek technical support 3 Seek technical support 4 Seek technical s...

Page 7: ...ning 3 Set P9 40 and P9 41 correctly based on the actual situation 7 Function Code Table Function Code Table EC670 Faults and solutions EC670 9 10 A0 Basic parameter group Address Function Code Settin...

Page 8: ...S2 terminal function 1201H 3 0 56 0 No function 1 Forward RUN FWD 2 Reverse RUN REV 3 Three line control 4 Forward JOG FJOG 5 Reverse JOG RJOG A1 Start stop and frequency parameter group Setting Rang...

Page 9: ...00 1208H A2 03 S4 terminal function 16 1203H A2 04 S5 terminal function 17 1204H A2 05 S6 terminal function 18 1205H A2 06 S7 terminal function 19 1206H A2 07 S8 terminal function 53 1207H A2 09 S1 S4...

Page 10: ...s run freq lmt Ups direction check frequency delay 1 0 10 0 During the acceleration process of UPS mode startup the maximum value of forward torque is detected If the value is exceeded the direction o...

Page 11: ...5 12 Encoder type 150CH 0000 A5 13 Encoder pulses per revolution 150DH 1024 0 60000 A5 21 Vector control slip gain 30 200 For the speed sensorless vector control this parameter is used to adjust the s...

Page 12: ...adjustment proportional gain 2000 151AH A5 27 Excitation adjustment integral gain 1300 151BH A5 28 Torque adjustment proportional gain 2000 151CH A5 29 Torque adjustment integral gain 1300 151DH 0000...

Page 13: ...V_DEC_SPEED 7 ERROR_OV_CONST_SPEED 8 ERROR_BUFFER_RES 9 ERROR_UV 10 ERROR_OL_INVERTER 11 ERROR_OL_MOTOR A8 04 1804H Only read 1st fault type 21 22 Function Code Table EC670 EC670 Function Code Table A...

Page 14: ...is function is used to give a warning signal to the control system through y before the motor overload fault protection The early warning coefficient is used to determine the degree of early warning b...

Page 15: ...bit0 power on time arrival err29 action selection Same place Led bit0 load loss err30 action selec tion 0 emergency stop fault alarm 1 emergency stop fault alarm 2 directly jump to 7 of the rated fre...

Page 16: ...y read Ao1 output value PU 35 2123H Only read Ao2 output value PU 36 2124H Only read HDO output value PU 37 2125H Only read Reserved PU 38 2126H Only read Module temperature PU 39 2127H Only read Outp...

Page 17: ...e output Y3 Y4 YC Shielded twisted pair Close to AC drive ground terminal Coil Coil PLC Shielded twisted pair Close to AC drive ground terminal AC200V ACOV Coil Shielded twisted pair Close to AC drive...

Page 18: ...maximum input frequency of 50KHz 4 Port Y4 is restricted by function parameter P5 32 which can be used as high speed pulse input channel with maximum input frequency of 50KHz 1 2 Standard wiring diagr...