F u n c t i o n C o d e T a b l e
EC670
EC670
F u n c t i o n C o d e T a b l e
A2
-
14
A2
-
15
Y2 terminal
function
Y3 terminal
function
120EH
120FH
14:Software current limit exceeded
15:Torque limited
16:Motor overload pre-warning
17:AC drive overload pre-warning
18:Zero-speed running (no output at stop)
19:Acceleration runing
20:Deceleration runing
21:Dc breaking
22:PLC step complete
23:PLC cycle complete
24:Resv
25:Accumulative running time reached
26:Timing reached
27:Designated count value reached
28:Set count value reached
29:AI1 input limit exceeded
30:Module temperature reached
31:Fan runing
32:From com do1
33、From com do2
34:From com do3
35:From com do4
36:Output uvw contactor enable
37:Mechanical brake contactor enable
38:Pre open door enable
36
5
A4
-
00
0000
~
0011
LED-Bits0:
0:Lift control disable
1:Lift control enable
LED-Bits1:
0:UPS active change direction mb disable
1:UPS active change direction mb enable
LED-Bits2:reserve
LED-Bits3:reserve
0110
1400H
Lift control
mode
A2
-
16
Y4 terminal
function
1210H
5
A3
Communication parameter group
Function
Code
Parameter Name
Setting Range
Default
Address
A3
-
00
Address
1300H
1
~
247
1
A3
-
01
Baud rate sel
1301H
0
~
8
5
A3
-
02
Data format
1302H
0
~
5
3
A3
-
03
1303H
0
~
7
3
A3
-
04
Communication
response delay
1304H
0
.
000
~
0.500
0.000s
A3
-
05
Communication
response delay
1305H
0.1
~
100
.
0
1.0s
A3
-
06
Transmission
response
processing
1306H
0
~
1
0
A4
Holding brake and UPS parameter group
Function
Code
Parameter Name
Setting Range
Default
Address
A4
-
01
0~10.0s
The maintenance time of detecting torque
direction frequency during UPS mode startup
acceleration
0~100%-hz
Operating frequency in UPS mode
1.0
6Hz
A4
-
05
1401H
1405H
Ups run
freq lmt
Ups direction
check frequency
delay
1
.
0
~
10.0%
During the acceleration process of UPS mode
startup, the maximum value of forward torque
is detected. If the value is exceeded, the
direction of operation will be switched
5.0%
A4
-
06
1406H
Ups dir
check torque
lmt
A4
-
07
0
.
05s
1407H
Ups dir check
refe torque
filter time
0
.
01
~
1
.
00s
Current output torque is collected in normal
operation mode for reference of direction
identification when switching into UPS mode.
This value is the filtering time when
collecting torque.
1.0~10.0s
Acceleration time in UPS mode
3.0s
A4
-
02
1402H
Ups acc time
1.0~10.0s
Deceleration time in UPS mode
2.0s
A4
-
03
1403H
Ups dec time
1
.
00~20.00Hz
Refer to the maximum frequency
5.00Hz
A4
-
04
1404H
Ups dir
check freq
A4
-
08
150%
1408H
Ups mode
torque lmt
50
~
150
%
The maximum value of forward torque during
UPS mode operation. When the value is
exceeded, the output frequency will be
reduced
A4
-
09
160V
1409H
Ups mode
Uu val
50
~
100
%
-Voltage
100% = undervoltage value in 350vdc UPS
mode
A4
-
10
/
140AH
Ups Torque
record value
(-
150)
~
150
%
only
read
Output torque value collected in normal
operation mode
A4
-
11
/
140BH
Ups direction
record value
Only reay
Operation direction of acquisition in normal
operation mode
A4
-
12
2.0s
140CH
Ups dir change
dc break time
0
~
10.0
DC braking time when torque exceeds the
maximum value of a4-09 forward torque
during startup acceleration in UPS mode
A4
-
13
50%
140DH
Ups dir change
dc break
current
0
~
150%
DC braking current in reverse direction
when torque exceeds a4-09 maximum forward
torque during UPS mode startup acceleration
A5
Motor parameters and vector control parameters group
Function
Code
Parameter Name
Setting Range
Default
Address
A5
-
00
0
1500H
Auto-tuning
selection
0
~
3
In order to obtain better VF or vector con-
trol performance, it is necessary to tune
the motor parameters, and the accuracy of