29
:
PID target value switchover terminal2
30
:
PID target value switchover terminal3
31
:
PID feedback value switchover terminal1
32
:
PID feedback value switchover terminal2
33
:
PID feedback value switchover terminal3
34
:
PLC pause 35
:
PLC status reset
36
:
Swing enable 37
:
Swing pause
38
:
Swing reset
39
:
Frequency source switchover terminal1
40
:
Frequency source switchover terminal2
41
:
Frequency source switchover terminal3
42
:
Frequency source switchover terminal4
43
:
Command source switchover terminal 1
44
:
Command source switchover terminal 2
45
:
Counter input terminal
46
:
Counter reset terminal
47
:
Counter clock input terminal
48
:
Counter reset
49
:
DC braking command
50
:
Terminal pre-excitation
51: User-defined fault1
52: User-defined fault2
53: Full water level signal terminal
54: Zero water level signal terminal
55: Forced switch to power frequency(closed
switch to power frequency, open input mode
controlled by operation panel)
P4
-
04
S5 terminal
function
54
0404H
P4
-
05
S6 terminal
function
55
0405H
P4
-
06
S7 terminal
function
10
0406H
P4
-
07
S8 terminal
function
11
0407H
040AH
P4
-
10
0000
BIT0: S5 terminal
0: Effective closing
1: Effective opening
BIT1: S6 terminal
0: Effective closing
1: Effective opening
BIT2: S7 terminal
0: Effective closing
1: Effective opening
BIT3: S8 terminal
0: Effective closing
1: Effective opening
Characteristic
selection of
terminal S5-S8
Characteristic
selection of
terminal S1-S4
0408H
P4
-
08
0000
BIT0: S1 terminal
0: Effective closing
1: Effective opening
BIT1: S2 terminal
0: Effective closing
1: Effective opening
BIT2: S3 terminal
0: Effective closing
1: Effective opening
BITE: S4 terminal
0: Effective closing
1: Effective opening
0409H
P4
-
09
0.10s
0.000
~
60.00s
This parameter is defined as the size of
filtering the input signal to eliminate the
interference signal. The longer the filtering
time is, the stronger the anti-interference
ability is, but the slower the response speed
is; the shorter the filtering time is, the
weaker the anti-interference ability is, but
the faster the response speed is.
Filter time of
terminal S1-S4
040BH
P4
-
11
0.01s
0.000
~
60.00s
Same as P4-08
Filter time of
terminal S5-S8
0: Two-line mode 1
Terminal set as 1 is forward running,
terminal set as 2 is
reverse running
1: Two-line mode 2
Terminal set as 1 is start running,
terminal set as 2 is switch forward and reverse
running
2: Three-line mode 1
Terminal set as 1 is forward running,
terminal set as 2 is reverse running,
terminal set as 3 is stop running
3: Three-line mode 2
Terminal set to 1 is start running, terminal
set as 2 is switch forward reverse, terminal
set as 3 is Stop running
P4
-
12
Terminal
command mode
040CH
0
P4
-
13
Terminal
action mode
selection
040DH
0111
P4
-
16
Terminal
protection
function
selection
BIT0
:
0: Invalid terminal operation command when power
on
1
:
Valid terminal operation command when power on
BIT1: When the run command
setting channel
terminal switching,selection of run command is
valid
0: The running command is valid after stopping
during switching
1: The run command is valid immediately when
switching
0000
0410H
BIT0: Terminal of coast to stop recovery mode
0: Restore the original instruction after
invalidation
1: Do not restore the original instruction
after invalidation
BIT1: Terminal of emergency stop recovery mode
0: Restore the original instruction after
invalidation
1: Do not restore the original instruction
after invalidation
BIT2: Select the terminal operation mode after
fault reset
0: The terminal operation command is valid
immediately
1: The terminal operation command is valid
only after it is canceled
P4
-
14
Reserved
-
-
040EH
P4
-
15
Reserved
-
-
040FH
P4
-
17
P4
-
18
UP/DW frequency
value
UP /DW frequency
adjustment
selection
0.0
~
100.0%
P4-23*maximum frequency=actual output frequency
0: Retentive at power failure
1: Non-retentive at power failure
2: Valid operation, stop and reset
0.0%
0
0411H
0412H
-
1 7
-
-
18
-
F u n c t i o n C o d e T a b l e
EC620
EC620
F u n c t i o n C o d e T a b l e