![E-Mu Proteus 1000 Operation Manual Download Page 170](http://html.mh-extra.com/html/e-mu/proteus-1000/proteus-1000_operation-manual_518563170.webp)
162
E-MU Systems
Save/Copy Menu
Sound Authoring
Duplicate Flash
This utility allows you to duplicate Flash SIMMs using Proteus 1000. Both
Sound and Preset data is copied when a Flash SIMM is duplicated. A factory
sound SIMM cannot be copied using this utility.
WARNING: dangerous voltages are exposed inside Proteus 1000!
Make
sure power is completely disconnected from Proteus 1000 before removing
the top panel.
Replace the top panel before restoring power to the unit.
The two sound SIMM sockets in Proteus 1000 are marked 0 and 1. These are
located behind the controller knobs on the circuit board. The Flash SIMM
you want to copy MUST be placed into SIMM Socket 0. The destination
Flash SIMM must be placed in SIMM socket 1.
1.
Make sure the two Flash SIMM are located in the required Proteus 1000
SIMM sockets.
_
_
_
_
If there are no Flash
SIMMs in the unit, or if the
SIMMs are in the wrong slots,
an error message will be
displayed.
2.
Press the Save/Copy menu button.
3.
Rotate the Data Entry Control to select the “Duplicate Flash SIMM”
screen shown above.
4.
Move the cursor to the bottom line and press Enter. The following
screen appears and the Enter LED will be flashing.
5.
Press Enter again to confirm or any other button to abort. The
following screen appears and the SIMM is copied.
6.
When Proteus 1000 has finished duplicating the SIMM, turn power off,
remove the copied SIMM, then reboot. That’s it!
DUPLICATE SLOT 0 FLASH
Start
Press ENTER to overwrite
the Flash SIMM in Slot 1
DUPLICATING SLOT 0 -> SLOT 1
(Takes about 5 minutes)