D 26
Energy saving mode / "Energy saving"
In this operating status, not all of the different screed sections' heaters are active at
the same time.
Switching is carried out via temperature regulation. Whenever the nominal tempera-
ture is achieved in an actively heated section, the control system switches these sec-
tions off and activates those with the lowest temperature.
It is possible to heat the following sections together in this case.
-
Section 1 and section 3
-
Section 2 and section 4
-
Section 1 and section 4
-
Section 2 and section 3
-
Section 1 and section 2
A
After switching on, the "Energy saving" status (ON/OFF) set during previous opera-
tion is assumed again.