9.2 Starting the engine with jump leads
NOTICE!
A wrong connection will cause severe damage
in the electric system.
–
Bridge the machine only with a 12 Volt auxiliary
battery.
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
n
Hearing protection
1.
Remove the cap from the plus pole of the battery.
2.
Flip open the cap of the pole clamp (minus pole).
3.
First connect the plus pole of the external battery to the plus
pole of the starter battery using the first jump lead.
4.
Next, connect the second jump lead to the minus pole of the
energizing external battery and then to the minus pole of the
starter battery.
5.
Start the engine:
Chapter 6.2 ‘Starting the engine’
6.
After starting, disconnect the minus poles first and the plus
poles after.
7.
Fold down the caps or put them on again.
B-834-0343
Fig. 129
B-016-0055
Fig. 130
B-ELE-0027
12 V
Fig. 131
Troubleshooting – Starting the engine with jump leads
DTR75D
111
Summary of Contents for DTR75D
Page 6: ...10 Disposal 119 10 1 Final shut down of machine 120 Table of contents DTR75D 6 ...
Page 7: ...1 Introduction Introduction DTR75D 7 ...
Page 11: ...2 Technical data Technical data DTR75D 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DTR75D 15 ...
Page 42: ...Concerning your safety Signage DTR75D 42 ...
Page 43: ...4 Indicators and control elements Indicators and control elements DTR75D 43 ...
Page 50: ...Indicators and control elements Engine DTR75D 50 ...
Page 51: ...5 Checks prior to start up Checks prior to start up DTR75D 51 ...
Page 61: ...6 Operation Operation DTR75D 61 ...
Page 75: ...7 Loading transporting the machine Loading transporting the machine DTR75D 75 ...
Page 80: ...Loading transporting the machine After transportation DTR75D 80 ...
Page 81: ...8 Maintenance Maintenance DTR75D 81 ...
Page 109: ...9 Troubleshooting Troubleshooting DTR75D 109 ...
Page 118: ...Troubleshooting Engine malfunctions DTR75D 118 ...
Page 119: ...10 Disposal Disposal DTR75D 119 ...
Page 121: ......
Page 122: ......