7.
Unscrew the filter housing.
8.
Take out the old filter element and clean the filter housing.
9.
Clean the thread on the filter housing.
10.
Reassemble the filter housing with a new filter element and a
new O-ring.
11.
Tighten the filter housing.
12.
Clean the area around the cover (2).
13.
Remove the screws (1) and take off the cover.
14.
Remove the suction filter (4) and replace it.
15.
Attach the cover with a new seal (3) and fasten the screws.
16.
Tighten the screws crosswise in the correct sequence
(1 - 10), tightening torque: 15 Nm (11 ft·lbf).
17.
Then retighten the screws in the same sequence, tightening
torque: 35 Nm (26 ft·lbf).
Replacing the hydraulic oil filter
B-834-0312
Fig. 114
Replacing the suction filter
1
2
3
4
B-834-0217
Fig. 115
3
10
1
7
4
9
8
2
6
5
15 Nm
35 Nm
B-834-0313
Fig. 116
Maintenance – Every 2 years / every 500 operating hours
DTR75D
101
Summary of Contents for DTR75D
Page 6: ...10 Disposal 119 10 1 Final shut down of machine 120 Table of contents DTR75D 6 ...
Page 7: ...1 Introduction Introduction DTR75D 7 ...
Page 11: ...2 Technical data Technical data DTR75D 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DTR75D 15 ...
Page 42: ...Concerning your safety Signage DTR75D 42 ...
Page 43: ...4 Indicators and control elements Indicators and control elements DTR75D 43 ...
Page 50: ...Indicators and control elements Engine DTR75D 50 ...
Page 51: ...5 Checks prior to start up Checks prior to start up DTR75D 51 ...
Page 61: ...6 Operation Operation DTR75D 61 ...
Page 75: ...7 Loading transporting the machine Loading transporting the machine DTR75D 75 ...
Page 80: ...Loading transporting the machine After transportation DTR75D 80 ...
Page 81: ...8 Maintenance Maintenance DTR75D 81 ...
Page 109: ...9 Troubleshooting Troubleshooting DTR75D 109 ...
Page 118: ...Troubleshooting Engine malfunctions DTR75D 118 ...
Page 119: ...10 Disposal Disposal DTR75D 119 ...
Page 121: ......
Page 122: ......