Maintenance - Every 2,000 hours
100
4812325557EN
2018-02-19
Replace the engine coolant
Caution! Risk of severe burns!
Wait until the engine temperature cools down to
122 F (50°C) before removing the coolant tank
cap or draining the coolant system.
1.
Open the expansion tank cap.
NEVER open the coolant tank cap when the
engine is hot.
2. Drain the engine coolant system through the cooler valve
drain.
3. Use a proper container to collect the coolant (with 3.69 gal
or 14 liters of capacity).
Be careful when draining the product. Use gloves
and protective goggles.
TAKE CARE OF THE ENVIRONMENT: All used
coolant shall be properly collected and store for
subsequent recycling. Do not dispose of the
coolant on the ground, sewage system or other
place which can harm the environment.
4. Unscrew the hexagon nut (1), remove the hose (2) and
unscrew the drain plug (4). Drain all the fluid to the
container.
5. After the replacement, tighten the drain plug (4) and fit back
the hose and the hexagon nut (1).
Fig. - Drain plugs
1. Hexagon nut
2. Hose
3. Drain plug
1
3
2