6
CA 262/362/512 M262EN2
Opening pressure,
MPa (psi)
CA262/362
CA512
Drive system
38,0(5,500)
38,0(5,500)
Charge system
2,0(290)
2,0(290)
Vibration system
40(5,800)
37,5(5,400)
Steering system
18,0(2,600)
18,0(2,600)
Brake release
1,4(200)
1,4(200)
TECHNICAL SPECIFICATIONS
Tightening torque
Tightening torque in Nm (lbf.ft) for oiled, bright
galvanized bolts tightened with a torque wrench.
Hydraulic system
Bolt size:
M24 (P/N 90 39 64)
Strength class:
10,9
Tightening torque: 800 Nm (590 lbf.ft)
(for Dacromet treated)
ROPS
ROPS bolts must
always
be tightened dry.
M
STRENGTH CLASS
thread
8.8
10.9
12.9
M6
8,4 (6.2)
12 (8.9)
14,6 (10.8)
M8
21 (15.5)
28 (20.7)
34 (21.1)
M10
40 (15.5)
56 (41.3)
68 (25.1)
M12
70 (51.6)
98 (72.3)
117 (86.3)
M16
169 (124.7)
240 (177)
290 (213.9)
M20
330 (243.4)
470 (346.7)
560 (413.1)
M24
570 (420.4)
800 (590.1)
960 (708.1)
M30
1130 (833.5) 1580 (1165.4) 1900 (1401.4)
M36
1960 (1445.7) 2800 (2065.3)
–
Air conditioner (Optional)
The system described in this manual is of the ACC
type (Automatic Climate Control), ie, a system that
maintains the set temperature in the cab, on condition
that windows and doors are kept closed.
Refrigerant designation: HFC-R134:A
Weight of refrigerant when newly filled CA262/362/
512=1600 gram