37
CA 262/362/512 M262EN2
ELECTRICAL SYSTEM, FUSES, RELAYS
Main fuses
Fig. 64 Engine compartment
1. Starter relay
2. Main fuses
3. Preheater relay
4. Fuses for preheater
There are three main fuses (2). These are located
behind the battery master disconnect switch. The three
screws need to be unscrewed to remove the plastic
cover.
The fuses are of the flat pin type.
The starter relay (1), preheater relay (3) and fuses for
the preheater relays (4) are also fitted here.
Supply, standard
30 A (Green)
Supply, cab
50 A (Red)
Supply, lighting
40 A (Orange)
Preheater supply relay 125 A (Orange)
Fuses in the cab
Fig. 63 Fuse box overhead in cab
20A
1. Condenser fans, cab roof
10A
2. Radio
5A
3. Cab interior lighting
25A
4. Air conditioner fan
10A
5. Rear screen wiper/screen-wash
10A
6. Front screen wiper/screen-wash
The electric system in the cab is equipped with its own
fuse box, located overhead at the front right part of the
cab.
The figure shows the ampere rating and function of the
different fuses. All fuses are of the flat pin type.
K2
VBS relay
K3
Main relay
K4
Horn relay
K5
Hourmeter relay
K6
Fuel level relay
K7
Reverse alarm relay
K8
Lights relay
K9
Direction indicator relay
K10
Brakes relay
= Optional
Relays
Fig. 65 Instrument panel
1
2
3
4
Summary of Contents for CA 262 Series