19
CA 262/362/512 M262EN2
EVERY 250 HOURS OF OPERATION (Monthly)
Rear axle differential
– Check oil level
Never work under the roller with the engi-
ne running. Park on a level surface. Block
the wheels securely.
Wipe clean and remove the level plug (1) and check
that the oil level reaches the lower edge of the plug
hole. Top off with oil to the right level if the level is low.
Use transmission oil according to the lubricant
specification.
1
1
Fig. 22 Oil level check – differential housing
1. Oil level/Filler plug
Rear axle planetary gears
– Check oil level
Fig. 23 Oil level check – planetary gear
(CA 262-362 Std.)
1. Oil level/Filler plug
Position the roller with the level plug (1) in the planetary
gears at 9 o’clock.
Wipe clean and remove the level plug (1) and check that
the oil level reaches the lower edge of the plug hole. Top
off with oil to the right level if the level is low. Use trans-
mission oil according to the lubricant specification.
Check the oil level in the same way in the rear axle’s
other planetary gear.
1
Fig. 24 Oil level check – planetary gear
(CA 512 std) (CA 262-362 optional)
1. Oil level/Filler plug
Summary of Contents for CA 262 Series
Page 2: ...19 ILF015WO1 ...